Back Button FL7740 Datasheet HTML 7Page - ON Semiconductor FL7740 Datasheet HTML 8Page - ON Semiconductor FL7740 Datasheet HTML 9Page - ON Semiconductor FL7740 Datasheet HTML 10Page - ON Semiconductor FL7740 Datasheet HTML 11Page - ON Semiconductor FL7740 Datasheet HTML 12Page - ON Semiconductor FL7740 Datasheet HTML 13Page - ON Semiconductor FL7740 Datasheet HTML 14Page - ON Semiconductor FL7740 Datasheet HTML 15Page - ON Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 16 page
background image
FL7740
www.onsemi.com
10
Primary Side Constant Voltage Regulation
FL7740 utilizes auxiliary winding to detect output
voltage during secondary side diode conduction time
(=TDIS). The true output voltage level without secondary
diode forward voltage drop is at the end of secondary
diode conduction time. In order to detect the right output
voltage, 85% of TDIS at previous switching cycle is
sampling time for VEAV detection at current switching
cycle.
S/H
VS
VREF
Error
Amp.
VEAV
COMV
TDIS
detection
Duty
Control
NAUX
VIN.PK
Figure 15. Primary Side Regulation
VS
GATE
85% TDIS
at previous
switching
TDIS
VEAV sampling
Figure 16. VEAV Detection
The sampled VEAV is compared with 3.5 V VREF at the
input of the error amplifier. Several hundreds nF
capacitor is connected to the output of the error amplifier
at COMV pin to keep feedback loop slow in PFC control.
COMV voltage controls duty to regulate VEAV same as
VREF in the system.
Turn-on time is controlled by both COMV voltage and
VIN.PK information in line feedforward operation in order
to keep the constant COMV voltage in the wide input
voltage range. So, turn-on time is proportional to COMV
voltage and inversely proportional to VIN.PK.
Startup
After plug-in, external VDD capacitor is quickly
charged by internal HV biasing supply. Even after VDD
is higher than 16 V VDD-ON, internal HV biasing is still
enabled for 500 ms, so HV biasing can relieve VDD
capacitor discharging until auxiliary winding builds up
VDD voltage.
In order to speed up large output capacitor charging
without overshoot, FL7740 starts with proportional gain
during startup sequence (SS1 + SS2) by using internal
resistive load at the output of the error amplifier.
In SS1, CCM prevent operation is enabled for the initial
2 ms. When output voltage is 0 V, deep CCM could be
entered at initial startup and CS could touch OCP level
with startup failure. So, pulse-by-pulse current limit is
0.2 V and switching frequency is 22 kHz during the 2 ms
CCM prevent time. Also, duty is gradually increased for
26 ms for soft startup. Once 5 V pulled-up COMV
voltage drops less than 4.5 V as VEAV is close to VREF,
SS1 is ended. Maximum SS1 time is limited up to 100
ms.
In SS2, VCOMV drops from 5 V and goes into p-gain
steady state in which VEAV is little bit lower than VREF
due to the error amplifier input error in p-gain. Once p-
gain steady state is settled down in 45 ms, SS2 is
finished at min. VCOMV range not to make overshoot
when transitioning to i-gain after SS2. FL7740 ends SS2
by monitoring VIN 1.5 ms after VIN.PK detection moment
where VCOMV is generally in the min. range.
VCOMV
Duty
VEAV
VIN
VREF
Startup time by P-gain
I-gain
45 ms
4.5 V
26 ms soft start
2 ms CCM prevent
5.0 V
VIN.PK
1.5 ms
SS1
SS2
Figure 17. Startup Sequence
Dynamic CV Regulation
Due to the narrow loop bandwidth, PFC controller
generally does not guarantee good CV regulation at load
transient. Especially in secondary side regulation,
primary side controller does not know the output voltage
level and it only monitors the output of feedback signal
through opto-coupler. Therefore, output voltage
undershoot is severely happened at no to full load
transient in the conventional SSR PFC control.
In order to overcome this, FL7740 utilizes the benefit of
PSR with ON semiconductor’s proprietary dynamic duty
control by monitoring the output voltage. For example,
when VEAV is less than VUVD.EN (Under Voltage Dynamic
Enable threshold), duty is quickly increased not to allow
undershoot anymore. Once VEAV rises higher than
VUVD.DIS (Under Voltage Dynamic Disable threshold),
duty quickly drops and follows COMV voltage. During
the VEAV hiccup operation, COMV voltage slowly
increases and dynamic operation is terminated when
COMV voltage is close to steady state level.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com