| Electronic Components Datasheet Search |
|
FL7740 Datasheet(PDF) 13 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
FL7740 Datasheet(HTML) 13 Page - ON Semiconductor |
|
13 / 16 page ![]() FL7740 www.onsemi.com 12 BIAS pin. Before 1 st switching, FL7740 converts the PF voltage into digital value without switching noise and keeps the digital value for the coefficient until UVLO is triggered. Recommended VPF is in Equation 1, where LM is magnetizing inductance and CEMI is total EMI filter capacitance. 1.5 10 5 V 9 PF EMI M C L (eq. 1) As VPF increases, the coefficient in the PF optimizer calculation is larger with better PF, but THD is worse due to the input current distortion at input voltage zero cross. Therefore, VPF adjustment by changing PF resistors is recommended to bring the best PF and THD performance to meet user’s target. When VPF is lower than 1.5 V, PF optimizer is disabled. IEMI.CAP IFLYBACK VIN IIN GATE TON Ideal IIN Figure 21. With PF Optimizer VIN IIN GATE TON IEMI.CAP IFLYBACK (=Ideal IIN) Leading phase Figure 22. Without PF Optimizer Protection Auto-restart Once protection is triggered, FL7740 terminates switching and internal 3 sec counter makes delay time. In 3 sec, VDD voltage is regulated between 17 V and 19 V by internal HV biasing not to fall in UVLO. After 3 sec, VDD falls down to 7.75 V VDD-OFF and IC is reset with released protection. When VDD voltage is up again to 16 V VDD-ON, FL7740 begins startup sequence. VDD GATE 19 V 17 V 7.75 V 16 V Protection triggered VDD regulation for 3 sec IC reset IC restart Figure 23. Auto Restart Output Over Voltage Protection Output over voltage is hardly triggered due to the powering limit by dynamic function. But, in the abnormal condition, output OVP is triggered when VEAV is higher than 4.0 V @ SET0 / 4.2 V @ SET1 for 4 switching cycles or VDD voltage is higher than 25 V for 10 us delay. Output Short Protection At output short condition, VEAV is less than 0.7 V. If this condition lasts for continuous 35 ms switching time, OSP is triggered. Over Current Protection When CS voltage is higher than 1.8 V over the 1.2 V pulse-by-pulse current limit, protection is immediately triggered. OCP protects output diode short, sensing resistor open and transformer saturation condition. Sensing Resistor Short Protection 1 st switching is 0.2 V current mode. If CS doesn’t reach over 75 mV threshold during 1 st turn-on time, SRSP is triggered. Max. turn-on time at 1 st switching is inversely proportional to input voltage to limit the primary peak current. Over Load Protection At over load condition, CS reaches to 1.2 V pulse-by- pulse current limit. FL7740 generates internal ZC (Zero Cross) signal and OLP is triggered if the event (1.2V current limit event between the two close ZC signals) is occurred for consecutive 60 ZC signals. VIN CS ZC OLP 1.2 V current limit event 1 0 0 2 3 58 57 59 60 OLP Count Figure 24. Over Load Protection Thermal Shut Down When internal junction temperature is higher than 150ºC, TSD is triggered and protection is released when the junction temperature drops under 120ºC. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |