23 / 37 page ![]() AD2S1210 Rev. A | Page 22 of 36 DOS RESET MAXIMUM AND MINIMUM THRESHOLD REGISTERS Table 16. 8-Bit Registers Address Bit Read/Write 0x8B D7 to D0 Read/write 0x8C D7 to D0 Read/write The AD2S1210 continuously stores the minimum and maximum magnitude of the monitor signal in internal registers. The differ- ence between the minimum and maximum is calculated to determine if a DOS mismatch has occurred. The initial values for the minimum and maximum internal registers must be defined by the user. When the fault register is cleared, the registers that store the maximum and minimum amplitudes of the monitor signal are reset to the values stored in the DOS reset maximum and minimum threshold registers. The resolution of the DOS reset maximum and minimum thresholds is seven bits each, that is, 38 mV. Note that the MSB, D7, should be set to 0.To ensure correct operation, it is recommended that the DOS reset minimum threshold register be set to at least 1 LSB less than the DOS overrange threshold, and the DOS reset maximum threshold register be set to at least 1 LSB greater than the LOS threshold register. The default value of the DOS reset minimum threshold register and the DOS reset maximum threshold register are 3.99 V and 2.28 V, respectively. LOT HIGH THRESHOLD REGISTER Table 17. 8-Bit Register Address Bit Read/Write 0x8D D7 to D0 Read/write The LOT high threshold register determines the loss of position tracking threshold for the AD2S1210. The LOT high threshold is a 7-bit word. Note that the MSB, D7, should be set to 0. The range of the LOT high threshold, the LSB size, and the default value of the LOT high threshold on power-up are dependent on the resolution setting of the AD2S1210, and are outlined in Table 19. LOT LOW THRESHOLD REGISTER Table 18. 8-Bit Register Address Bit Read/Write 0x8E D7 to D0 Read/write The LOT low threshold register determines the level of hysteresis on the loss of position tracking fault detection. Loss of tracking (LOT) occurs when the internal error signal of the AD2S1210 exceeds the LOT high threshold. LOT has hysteresis and is not cleared until the internal error signal is less than the value defined in the LOT low threshold register. The LOT low threshold is a 7-bit word. Note that the MSB, D7, should be set to 0. The range of the LOT high threshold, the LSB size, and the default value of the LOT high threshold on power-up are dependent on the resolu- tion setting of the AD2S1210, and are outlined in Table 19. Table 19. LOT High/Low Threshold Resolution (Bits) Range (Degrees) LSB Size (Degrees) LOT Low Default (Degrees) LOT High Default (Degrees) 10 0 to 45 0.35 2.5 12.5 12 0 to 18 0.14 1.0 5.0 14 0 to 9 0.09 0.5 2.5 16 0 to 9 0.09 0.5 2.5 EXCITATION FREQUENCY REGISTER Table 20. 8-Bit Register Address Bit Read/Write 0x91 D7 to D0 Read/write The excitation frequency register determines the frequency of the excitation outputs of the AD2S1210. A 7-bit frequency control word is written to the register to set the excitation frequency. Note that the MSB, D7, should be set to 0. ( ) CLKIN f Frequency Excitation FCW 15 2 × = (9) where FCW is the frequency control word and fCLKIN is the clock frequency of the AD2S1210. The specified range of the excitation frequency is from 2 kHz to 20 kHz and can be set in increments of 250 Hz. To ensure that the AD2S1210 is operated within the specified frequency range, the frequency control word should be a value between 0x4 and 0x50. For example, if the user requires an excitation frequency of 5 kHz and has an 8.192 MHz clock frequency, the code that needs to be programmed is given by ( ) 14 MHz 192 . 8 2 kHz 5 15 = × = FCW (hexadecimal) The default excitation frequency of the AD2S1210 on power-up is 10 kHz. CONTROL REGISTER Table 21. 8-Bit Register Address Bit Read/Write 0x92 D7 to D0 Read/write The control register is an 8-bit register that sets the AD2S1210 control modes. The default value of the control register on power-up is 0x7E. Table 22. Control Register Bit Descriptions Bit Description D7 Address/data bit D6 Reserved; set to 1 D5 Phase lock range 0 = 360°, 1 = ±44° D4 0 = disable hysteresis, 1 = enable hysteresis D3 Set Encoder Resolution EnRES1 D2 Set Encoder Resolution EnRES0 D1 Set Resolution RES1 D0 Set Resolution RES0 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |