| Electronic Components Datasheet Search |
|
LTC4259A Datasheet(PDF) 11 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC4259A Datasheet(HTML) 11 Page - Linear Technology |
|
11 / 32 page ![]() LTC4259A 11 4259Af disconnect enabled independently of the state of the Osc Fail bit. See AC Disconnect under Applications Information for more details. Bit 4 indicates that VEE has dropped be- low the VEE UVLO level (typically –28V). Bit 5 signals that the VDD supply has dropped below the VDD UVLO thresh- old. Bit 7 indicates that the LTC4259A die temperature has exceeded its thermal shutdown limit (see Note 5 under Electrical Characteristics). The logical OR of bits 1, 4, 5 and 7 appears in the Interrupt register as the Supply Fault bit. See the Misc Config register for information on masking the Osc Fail bit out of the Supply Fault interrupt. The remaining bits in the register are reserved and will always read as 0. The Supply Event bits latch high and will remain high until cleared by reading from address 0Bh. Supply Event CoR (Address 0Bh): Supply Event Register, Clear on Read. Read this address to clear the Fault Event register. Address 0Bh returns the same data as address 0Ah, and reading address 0Bh clears all bits at both addresses. Status Registers Port 1 Status (Address 0Ch): Port 1 Status Register, Read Only. This register reports the most recent detection and classification results for port 1. Bits 0-2 report the status of the most recent detection attempt at the port and bits 4-6 report the status of the most recent classification attempt at the port. If power is on, these bits report the detection/ classification status present just before power was turned on. If power is turned off at the port for any reason, all bits in this register will be cleared. See Table 1 for detection and classification status bit encoding. Port 2 Status (Address 0Dh): Port 2 Status Register, Read Only. See Port 1 Status. Port 3 Status (Address 0Eh): Port 3 Status Register, Read Only. See Port 1 Status. Port 4 Status (Address 0Fh): Port 4 Status Register, Read Only. See Port 1 Status. Power Status (Address 10h): Power Status Register, Read Only. The lower four bits in this register report the switch on/off state for the corresponding ports. The upper four bits (the power good bits) indicate that the drop across the power switch and sense resistor for the corresponding ports is less than 2V (typ) and power start-up is complete. The power good bits are latched high and are only cleared when a port is turned off or the LTC4259A is reset. Pin Status (Address 11h): External Pin Status, Read Only. This register reports the real time status of the AUTO (Pin 35) and AD0-AD3 (Pins 7-10) digital input pins. The logic state of the AUTO pin appears at bit 0 and the AD0-AD3 pins at bits 2-5. The remaining bits are reserved and will read as 0. AUTO affects the initial states of some of the LTC4259A configuration registers at start-up but has no effect after start-up and can be used as a general purpose input if desired, as long as it is guaranteed to be in the appropriate state at start-up. Configuration Registers Operating Mode (Address 12h): Operating Mode Configu- ration, Read/Write. This register contains the mode bits for each of the four ports in the LTC4259A. See Table 1 for mode bit encoding. At power-up, all bits in this register will be set to the logic state of the AUTO pin (Pin 35). See Operating Modes in the Applications Information section. Disconnect Enable (Address 13h): Disconnect Enable Register, Read/Write. The lower four bits of this register enable or disable DC disconnect detection circuitry at the corresponding port. If the DC Discon Enable bit is set the port circuitry will turn off power if the current draw at the port falls below IMINformorethantDIS.IMINisequaltoVMIN/ RS, where RS is the sense resistor and should be 0.5Ω for IEEE 802.3af compliance. If the bit is clear the port will not remove power due to low current. The upper four bits enable or disable AC disconnect on the corresponding port. When a port’s AC disconnect bit is set, the LTC4259A senses the impedance of that port by forc- ing an AC voltage on the port’s DETECT pin and measuring the AC current. If the DETECT pin sinks less than IACDMIN for more than tDIS, the port will turn off power. If the bit is clear, the port will not remove power due to high port impedance (AC current below IACDMIN). The DC and AC disconnect signals that reset tDIS are ORed together and either sensing method (if they are both en- abled) will keep the port powered. A port with neither DC or AC disconnect enabled will not power off automatically when the PD is removed. REGISTER FU CTIO S |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |