Back Button LTC4259A Datasheet HTML 22Page - Linear Technology LTC4259A Datasheet HTML 23Page - Linear Technology LTC4259A Datasheet HTML 24Page - Linear Technology LTC4259A Datasheet HTML 25Page - Linear Technology LTC4259A Datasheet HTML 26Page - Linear Technology LTC4259A Datasheet HTML 27Page - Linear Technology LTC4259A Datasheet HTML 28Page - Linear Technology LTC4259A Datasheet HTML 29Page - Linear Technology LTC4259A Datasheet HTML 30Page - Linear Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 26 / 32 page
background image
LTC4259A
26
4259Af
While it is sending its address, it monitors the SDAIN pin
to see if another device is sending an address at the same
time using standard I2C bus arbitration. If the LTC4259A
is sending a 1 and reads a 0 on the SDAIN pin on the rising
edge of SCL, it assumes another device with a lower
address is sending and the LTC4259A immediately aborts
its transfer and waits for the next ARA cycle to try again.
If transfer is successfully completed, the LTC4259A will
stop pulling down the INT pin. When the INT pin is released
in this way or if a 1 is written into the Clear Interrupt pin bit
(bit 6 of register 1Ah), the condition causing the LTC4259A
to pull the INT pin down must be removed before the
LTC4259A will be able to pull INT down again. This can be
done by reading and clearing the event registers or by
writing a 1 into the Clear All Interrupts bit (bit 7 of register
1Ah). The state of the INT pin can only change between I2C
transactions, so an interrupt is cleared or new interrupts
are generated after a transaction completes and before
new I2C bus communication commences. Periodic polling
of the alert response address can be used instead of the
INT pin if desired. If any device acknowledges the alert
response address, then the INT line, if connected, would
have been low.
System Software Strategy
Control of the LTC4259A hinges on one decision, the
LTC4259A’s operating mode. The three choices are de-
scribed under Operating Modes. In Auto mode the
LTC4259A can operate autonomously without direction
from a host controller. Because LTC4259As running in
Auto mode will power every valid PD connected to them,
the PSE must have 15.4W/port available. To reduce the
power requirements of the –48V supply, PSE systems
can track power usage, only turning on ports when
sufficient power is available. The IEEE describes this as a
power allocation algorithm and places two limitations: the
PSE shall not power a PD unless it can supply the
guaranteed power for that PD’s class (see Table 2) and
power allocation may not be based solely on a history of
APPLICATIO S I FOR ATIO
each PD’s power consumption. In order for a PSE to
implement power allocation, the PSE’s processor/con-
troller must control whether ports are powered—the
LTC4259A cannot be allowed to operate in Auto mode.
Semiauto mode fits the bill as the LTC4259A automati-
cally detects and classifies PDs, then makes this informa-
tion available to the host controller, which decides to
apply power or not. Operating the LTC4259A in Manual
mode also lets the controller decide whether to power the
ports but the controller must also control detection and
classification. If the host controller operates near the limit
of its computing resources, it may not be able to guide a
Manual mode LTC4259A through detect, class and port
turn-on in less than the IEEE mandated maximum of
950ms.
In a typical PSE, the LTC4259As will operate in Semiauto
mode as this allows the controller to decide to power a
port without unduly burdening the controller. With an
interrupt mask of F4h, the LTC4259A will signal to the
host after it has successfully detected and classed a PD,
at which point the host can decide whether enough power
is available and command the LTC4259A to turn that port
on. Similarly, the LTC4259A will generate interrupts when
a port’s power is turned off. By reading the LTC4259A’s
interrupt register, the host can determine if a port was
turned off due to overcurrent (tSTART or tICUT faults) or
because the PD was removed (Disconnect event). The
host then updates the amount of available power to reflect
the power no longer consumed by the disconnected PD.
Setting the MSB of the interrupt mask causes the LTC4259A
to communicate fault conditions caused by failures within
the PSE, so the host does not need to poll to check that the
LTC4259As are operating properly. This interrupt driven
system architecture provides the controller with the final
say on powering ports at the same time, minimizing the
controller’s computation requirements because inter-
rupts are only generated when a PD is detected or on a
fault condition.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com