| Electronic Components Datasheet Search |
|
AD7490 Datasheet(PDF) 21 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7490 Datasheet(HTML) 21 Page - Analog Devices |
|
21 / 29 page ![]() AD7490 Data Sheet Rev. D | Page 20 of 28 Auto Shutdown (PM1 = 0, PM0 = 1) In this mode, the AD7490 automatically enters shutdown at the end of each conversion when the control register is updated. When the part is in shutdown, the track-and-hold is in hold mode. Figure 24 shows the general diagram of the operation of the AD7490 in this mode. In shutdown mode, all internal circuitry on the AD7490 is powered down. The part retains information in the control register during shutdown. The AD7490 remains in shutdown until the next CS falling edge it receives. On this CS falling edge, the track-and-hold that was on hold while the part was in shut- down mode returns to track-and-hold. Wake-up time from auto shutdown is 1 μs, and the user should ensure that 1 μs elapses before attempting a valid conversion. When running the AD7490 with a 20 MHz clock, one dummy cycle of 16 × SCLK should be sufficient to ensure the part is fully powered up. During this dummy cycle, the contents of the control register should remain unchanged; therefore, the WRITE bit should be 0 on the DIN line. This dummy cycle effectively halves the throughput rate of the part, with every other conversion result being valid. In this mode, the power consumption of the part is greatly reduced with the part entering shutdown at the end of each conversion. When the control register is programmed to move into auto shutdown, it does so at the end of the conversion. The user can move the ADC in and out of the low power state by controlling the CS signal. Auto Standby (PM1 = PM0 = 0) In this mode, the AD7490 automatically enters standby mode at the end of each conversion when the control register is updated. Figure 25 shows the general diagram of the operation of the AD7490 in this mode. When the part is in standby, portions of the AD7490 are powered-down, but the on-chip bias generator remains powered up. The part retains information in the control register during standby. The AD7490 remains in standby until it receives the next CS falling edge. On this CS falling edge, the track-and-hold that was on hold while the part was in standby returns to track. Wake-up time from standby is 1 μs; the user should ensure that 1 μs elapses before attempting a valid conver- sion on the part in this mode. When running the AD7490 with a 20 MHz clock, one dummy cycle of 16 × SCLK should be sufficient to ensure the part is fully powered up. During this dummy cycle, the contents of the control register should remain unchanged; therefore, the WRITE bit should be set to 0 on the DIN line. This dummy cycle effectively halves the throughput rate of the part with every other conversion result being valid. In this mode, the power consumption of the part is greatly reduced with the part entering standby at the end of each con- version. When the control register is programmed to move into auto standby, it does so at the end of the conversion. The user can move the ADC in and out of the low power state by controlling the CS signal. SCLK 116 116 116 DOUT DIN CS DUMMY CONVERSION CONTROL REGISTER IS LOADED ON THE FIRST 12 CLOCKS, PM1 = 0, PM0 = 1 CONTROL REGISTER CONTENTS SHOULD NOT CHANGE, WRITE BIT = 0 PART ENTERS SHUTDOWN ON CS RISING EDGE AS PM1 = 0, PM0 = 1 PART IS FULLY POWERED UP TO KEEP PART IN THIS MODE, LOAD PM1 = 0, PM0 = 1 IN CONTROL REGISTER OR SET WRITE BIT = 0 CHANNE L IDENTIFIER BITS + CONVERSION RESULT DATA IN TO CONTROL/SHADOW REGISTER CHANNE L IDENTIFIER BITS + CONVERSION RESULT DATA IN TO CONTROL/SHADOW REGISTER INVALID DATA PART ENTERS SHUTDOWN ON CS RISING EDGE AS PM1 = 0, PM0 = 1 PART BEGINS TO POWER UP ON CS FALLING EDGE Figure 24. Auto Shutdown Mode Operation SCLK 112 16 1 12 16 1 12 16 DOUT DIN CS DUMMY CONVERSION CONTROL REGISTER IS LOADED ON THE FIRST 12 CLOCKS, PM1 = 0, PM0 = 0 CONTROL REGISTER CONTENTS SHOULD REMAIN UNCHANGED, WRITE BIT = 0 PART IS FULLY POWERED UP TO KEEP PART IN THIS MODE, LOAD PM1 = 0, PM0 = 0 IN CONTROL REGISTER PART ENTERS STANDBY ON CS RISING EDGE AS PM1 = 0, PM0 = 0 PART ENTERS STANDBY ON CS RISING EDGE AS PM1 = 0, PM0 = 0 PART BEGINS TO POWER UP ON CS FALLING EDGE CHANNE L IDENTIFIER BITS + CONVERSION RESULT CHANNE L IDENTIFIER BITS + CONVERSION RESULT INVALID DATA DATA IN TO CONTROL/SHADOW REGISTER DATA IN TO CONTROL/SHADOW REGISTER Figure 25. Auto Standby Mode Operation |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |