18 / 21 page ![]() REV. E AD7660 –17– External Clock Data Read during Conversion Figure 20 shows the detailed timing diagrams of this method. During a conversion, while both CS and RD are LOW, the result of the previous conversion can be read. The data is shifted out, MSB first, with 16 clock pulses, and is valid on both the rising and falling edges of the clock. The 16 bits have to be read before the current conversion is complete; this, otherwise, RDERROR is pulsed HIGH and can be used to interrupt the host interface to prevent incomplete data reading. There is no daisy- chain feature in this mode, and RDC/SDIN input should always be tied either HIGH or LOW. To reduce performance degradation due to digital activity, a fast discontinuous clock of at least 18 MHz is recommended to ensure that all the bits are read during the first half of the conversion phase. For this reason, this mode is more difficult to use. MICROPROCESSOR INTERFACING The AD7660 is ideally suited for traditional dc measurement applications supporting a microprocessor, and for ac signal pro- cessing applications interfacing to a digital signal processor. The AD7660 is designed to interface either with a parallel 8-bit or 16-bit wide interface, or with a general-purpose serial port or I/O ports on a microcontroller. A variety of external buffers can be used with the AD7660 to prevent digital noise from coupling into the ADC. The following section discusses the use of an AD7660 with an ADSP-219x SPI equipped DSP. SDOUT CS SCLK D1 D0 X D15 D14 D13 12 3 14 15 16 t3 t35 t36 t37 t31 t32 t16 CNVST BUSY EXT/ INT = 1 INVSCLK = 0 RD = 0 Figure 20. Slave Serial Data Timing for Reading (Read Previous Conversion during Convert) SPI Interface (ADSP-219x) Figure 21 shows an interface diagram between the AD7660 and an SPI-equipped ADSP-219x. To accommodate the slower speed of the DSP, the AD7660 acts as a slave device and data must be read after conversion. This mode also allows the daisy- chain feature. The convert command can be initiated in response to an internal timer interrupt. The reading process cab be initi- ated in response to the end-of-conversion signal (BUSY going LOW) using an interrupt line of the DSP. The serial interface (SPI) on the ADSP-219x is configured for master mode— (MSTR) = 1, Clock Polarity bit (CPOL) = 0, Clock Phase bit (CPHA) = 1, and SPI Interrupt Enable (TIMOD) = 00— by writing to the SPI control register (SPICLTx). To meet all timing requirements, the SPI clock should be limited to 17 Mbps, which allows it to read an ADC result in less than 1 ms. When a higher sampling rate is desired, use of one of the paral- lel interface modes is recommended. SPIxSEL (PFx) ADSP-219x* CNVST AD7660* CS BUSY MISOx SCKx PFx or TFSx SDOUT SCLK RD INVSCLK EXT/ INT SER/ PAR DVDD *ADDITIONAL PINS OMITTED FOR CLARITY PFx Figure 21. Interfacing the AD7660 to an SPI Interface |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |