Electronic Components Datasheet Search
  English  ▼

X  

SA4305ASAR Datasheet(PDF) 11 Page - Sames

Part # SA4305ASAR
Description  Three Phase Bidirectional Energy Metering IC
PDF  15 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  SAMES [Sames]
Direct Link  http://www.sames.co.za
Logo SAMES - Sames

SA4305ASAR Datasheet(HTML) 11 Page - Sames

Back Button SA4305ASAR Datasheet HTML 7Page - Sames SA4305ASAR Datasheet HTML 8Page - Sames SA4305ASAR Datasheet HTML 9Page - Sames SA4305ASAR Datasheet HTML 10Page - Sames SA4305ASAR Datasheet HTML 11Page - Sames SA4305ASAR Datasheet HTML 12Page - Sames SA4305ASAR Datasheet HTML 13Page - Sames SA4305ASAR Datasheet HTML 14Page - Sames SA4305ASAR Datasheet HTML 15Page - Sames  
Zoom Inzoom in Zoom Outzoom out
 11 / 15 page
background image
SPEC-3093 (REV. 2)
11/15
29-09-2017
SA4305A
The four current input resistors (R3, R4, R5, R6) should be of
equal size to optimize the input networks low pass filtering
characteristics, so the values can be calculated as follows:
����3 = ����4 = ����5 = ����6 =
����������������
������������
×
��������
2 × 16��������
= 1.5����٠= ��������
For optimum performance the cut-off frequency of the anti-
alias filter should be between 10kHz and 20kHz. The
equivalent resistance associated with each capacitor is RC/2
so the capacitor values should be in the order of
����1 = ����2 =
1
������������������������
=
1
���� × 10������������ × 1.5����Ω
≈ 22�������� = ��������
where fCI is the cut-off frequency of the anti-alias filter of the
current input network.
The current input networks for channel 2 and channel 3 are
identical.
Voltage Input Networks
The voltage sense inputs should optimally be set to an input
current of 14
μARMS at VNOM (220V). The mains voltage is
divided by means of a voltage divider to a lower voltage that
is converted to the required input current by means of the
input resistor. Once again an anti-alias filter is required to
remove any high frequency signals that could affect the
performance of the SA4305A. The phase shift of the current
transformers is compensated by means of this anti-alias filter
as well, by purposefully increasing the cut-off frequency.
The input resistor R22 sets the current input into the device.
This resistor should not be too large else the capacitor for the
anti-alias filter will be quite small which could cause
inaccurate phase shift due to parasitic capacitances.
Therefore R22 = 100k
 is chosen and the voltage at the
centre of the trimpot should be 1.4V (14
μA x 100k
). The
calibration range of the voltage input network should be about
±15% to ensure that all component tolerances can be catered
for, so the total tuning range can be set to ±0.22V. Therefore
the voltage across the trimpot and R23 is 1.62V. Choosing a
1k
 trimpot results in
����23 =
1����Ω
(2 × 0.22)
× (1.62 − 2 × 0.22) ≈ 2.7����Ω
The effect of R22 can be ignored in the above equation, given
the fact that R22 is significantly larger than P1 and R23. Now
let RA = R19 + R20 + R21 and
�������� = (����1 + ����23) × (
220����
1.62����
− 1) ≈ 499����Ω
so choose R19 = R20 = 200k
 and R21 = 100k.
The cut-off frequency of the anti-alias filter is adjusted so that
the phase shift of the voltage input network is identical to the
sum of the phase shifts of the current transformer and the
current input network. The phase shift of the current input
network is
������������ = − tan−1(�������������������� × 50��������) ≈ −0.297°
The phase shift required on the voltage input network is
therefore
������������ = ������������ − ������������ = −0.297° + 0.09° = −0.207°
where
CT is the phase shift of the current transformer which
is typically about 0.09 degrees for a good quality current
transformer. Neglecting R19, R20, R21 and R22 because all
these resistors are significantly larger than P1 and R23 the
capacitance required to achieve the -0.207 degree phase
shift is
����7 =
|tan ������������|
2����(����1 + ����23) × 50��������
≈ 3.3��������
resulting in a cut-off frequency of
������������ =
1
2����(����1 + ����23) × ����7
≈ 13������������
The value of the cut-off frequency of the voltage input network
is less critical than that of the current input network because
the dynamic range of the voltage input is small. A cut-off
frequency between 10kHz and 25kHz is acceptable.
The voltage input networks for channel 2 and channel 3 are
identical
Device Setup
Depending on the desired output pulse format the four device
setup pins (PGM0, PGM1, MS and FPM) need to be
configured. These pins should be connected directly to either
VDD or VSS. The MS and FPM inputs have internal pull-down
resistors and may therefore be left floating. This will be
equivalent to connecting the pin to VSS. The TEST pin should
be left floating.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com