14 / 29 page ![]() Data Sheet 14 Revision 1.1, 2015-07-29 KP253 Digital Absolute Pressure Sensor Functional Description 2.7.2 Single Device Operation Figure 18 shows an example on how to connect a singe device to a microcontroller. After NCS is pulled to low, the request command is sent to the sensor with the next 16 cycles of the CLK. The response of the sensor for the previous request command is returned at the same time. The SPI signal timing is shown in Figure 19. Figure 18 Example for single device operation Figure 19 Example for single device signal timing µC KP25x NCS low for 16 CLK pulses NCS CLK MDI MDO COMMAND_n ANSWER_n-1 time 16 CLK cycles ... COMMAND_n+1 ANSWER_n 16 CLK cycles ... |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|