| Electronic Components Datasheet Search |
|
CDCLVD110 Datasheet(PDF) 5 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
CDCLVD110 Datasheet(HTML) 5 Page - Texas Instruments |
|
5 / 10 page ![]() CDCLVD110 PROGRAMMABLE LOW-VOLTAGE 1:10 LVDS CLOCK DRIVER SCAS684 – SEPTEMBER 2002 5 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 control register characteristics over recommended operating free-air temperature range, VDD = 2.5 V ±5% PARAMETER TEST CONDITIONS MIN TYP MAX UNIT fMAX Maximum frequency of shift register 100 150 MHz tsu Setup time, clock to SI 2 ns th Hold time, clock to SI 1.5 ns tremoval Removal time, enable to clock 1.5 ns tw Clock pulse width, minimum 3 ns VIH Logic input high VDD = 2.5 V 2 V VIL Logic input low VDD = 2.5 V 0.8 V I Input current, CK pin VV –5 5 A IIH Input current, SI and EN pins VI = VDD 10 30 µA I Input current, CK pin V GND –10 –30 A IIL Input current, SI and EN pins VI = GND –5 5 µA specification of control register The CDCLVD110 is provided with an 11-bit, serial-in shift register and an 11-bit control register. The control Register enables/disables each output clock and selects either CLK0 or CLK1 as the input clock. The CDCLVD110 has two modes of operation: Programmable Mode (EN=1) The shift register utilizes a serial input (SI) and a clock input (CK). Once the shift register is loaded with 11 clock pulses, the twelfth clock pulse loads the control register. The first bit (bit 0) on SI enables the Q9, Q9 output pair, and the tenth bit (bit 9) enables the Q0, Q0 pair. The eleventh bit (bit 10) on SI selects either CLK0 or CLK1 as the input clock; a bit value of 0 selects CLK0, whereas a bit value of 1 selects CLK1. To restart the control register configuration, a reset of the state machine must be done with a clock pulse on CK (shift register clock input) and EN set to low. The control register can be configured only once after each reset. Standard Mode (EN=0) In this mode, the CDCLVD110 is not programmable and all the clock outputs are enabled. The clock input (CLK0 or CLK1) is selected with the SI pin, as is shown in the table entitled control register. state-machine inputs EN SI CK OUTPUT L L X All outputs enabled, CLK0 selected, control register disabled, default state L H X All outputs enabled, CLK1 selected, control register disabled H L ↑ First stage stores L, other stage stores data of previous stage H H First stage stores H, other stage stores data of previous stage L X Reset of state machine, shift and control registers control register BIT 10 BITS [0–9] QN[0–9] L H CLK0 H H CLK1 X L Outputs disabled |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |