| Electronic Components Datasheet Search |
|
ACCTEE Datasheet(PDF) 10 Page - TOKYO SEIMITSU CO., LTD |
|
|
|||||||||||||||||||||||||||||
ACCTEE Datasheet(HTML) 10 Page - TOKYO SEIMITSU CO., LTD |
|
10 / 11 page ![]() Surface Texture – Contour Measuring Instruments Software Data processing software Contour Profile Measurement and Analysis System Pitch calculation Input range Pitch calculation Calculation result Master ball calibration unit Since the probe moves in a circular motion vertically around the support on the contour measuring instrument's probe arm, error will be produced in the X-axis data because the probe tip position also moves in the X-axis direction. These error elements must be corrected in order to achieve high measur- ing accuracy. The ACCRETECH contour measuring system performs calibration using a master ball calibration unit which enables simple circle error as well as tip R error calibration. Masterball calibration function Circle Correction Calculation Although the contour measuring instrument's probe tip is R-shaped, tip R-correction is indispensable for high measuring accuracy. Measurements are taken from the center of probe tip R and correction is performed by offsetting in the normal direction at 11 dividing points on the tip. Though there is no problem with fixed quantity correction when probe tip R is near maximal generalized roundness zero, large errors can occur in the correction amount due to tip R processing tolerance error or wear after long term use. Tip R-Correction Stylus calibration is performed by the masterball calibration unit. During masterball measurement and level difference measurement, tip R correction and arc error correction can be executed automatically or manually. The wizard takes you through all necessary steps in the following order: calibration condition (inputting reference value) setting, placement of the calibration unit, confirmation of measurement start point, and execution of calibration. Stylus Calibration Wizard Calibration can be specified at any time.. In addition to the stylus replacement time, a calibration alert based on mea- surement frequencies or elapsed time is displayed periodically, ensuring accurate, stable measurement on a continuous basis. Calibration Alert When analyzing the same profile repeatedly, it is possible to switch from manual operation to targeted analysis during CNC execution by setting the condition for recalculation, enabling detailed analysis. Calculation Point Manual Input For the same multiple profiles composed of circles and straight lines, the pitch between line intersections or the pitch between circle centers can be automatically output just by specifying the arc with the mouse. Analysis efficiency can be improved by using the dimension line auto output function at the same time. Pitch Calculation Function Workpiece height X-direction deviation Probe arm support Figure b Profile when new Profile after wear Master ball correction screen Probe Probe R center locus Probe R center locus Probe R-correction only in normal direction Post-correction data Figure a 62 TOKYO SEIMITSU |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |