| Electronic Components Datasheet Search |
|
SLC1 Datasheet(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
SLC1 Datasheet(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 6 page ![]() Wiring Diagrams Outputs ON during gap (Turn OFF at leading edge of label) Outputs ON during label (Turn ON at leading edge of label) Key 1 2 3 + – 4 5* Load Load 10-30 V dc 1 2 3 + – 4 5* Load Load 10-30 V dc 1 - brown 2 - white 3 - blue 4 - black 5 - gray *Toggle to opposite polarity for > 100 milliseconds to reset microprocessor. Specifications Supply Voltage and Current 10 to 30 V dc (10% max. ripple) @ less than 60 mA (exclusive of load ) Supply Protection Circuitry Protected against reverse polarity and transient voltages Power-Up or Reset Delay 1 second typical (outputs are non-conducting during this time) Output Configuration Bipolar: one current-sourcing (PNP) and one current-sinking (NPN) open-collector transistor Output Rating 150 mA max. (each output) OFF-state leakage current: < 5 microamps at 30 V dc Output saturation voltage: < 1 V at 10 milliamps dc; < 1.6 V at 150 milliamps dc Output Protection Protected against continuous overload and short-circuit of outputs Overload trip point: > 200 milliamps, typical, at 20 °C Output Invert Control/Reset Gray wire has dual functionality, and may be controlled by a PLC Input impedance: 10 KΩ Outputs ON during gap (turn OFF at leading edge of label): leave open, or connect to 0 to +1 V dc Outputs ON during label (turn ON at leading edge of label): connect to +5 to 30 V dc Microprocessor reset: toggle gray wire to opposite polarity for > 100 milliseconds Environmental Rating IP67, NEMA 6 Operating Conditions Temperature: 5 °C to 50 °C (41 °F to 122 °F) Maximum relative humidity: 90% at 50 °C, non-condensing Registration Accuracy ±0.3 mm (0.012 inch) typical, at web speeds up to 1.5 m per second (5 ft per second) 2 Maximum Counting Speed Web speed of 10 m per second (33 ft per second) 2 Minimum Sensing Speed Web speed of 100 mm per minute (4 inches per minute) 2 Response Time 100 μs 2 Maximum Switching Speed 1 kHz 2 Minimum Gap or Label Size 2 mm (0.08 inch) Adjustments No user adjustments; automatic continuous adjustment of sensing threshold and drift compensation under internal microprocessor control Adjustment interval: every 250 milliseconds or 4 labels, whichever is greater Indicators Two LEDs, green and amber Green ON: power to sensor is ON Green flashing at 4 Hz: output is overloaded Amber ON: NPN and PNP outputs are ON Green and amber flashing alternately at 1 Hz: internal error; reset sensor Construction Housings are machined aluminum with black anodized finish Connections 2 m (6.5 ft) or 9 m (30 inches) 5-wire attached cable, or 5-pin Euro- style quick-disconnect fitting Cables for QD models are purchased separately Certifications Approval expected: UL 2 Based on 3.2 mm (0.125 inch) gap between labels. Instantaneous web speed, not average web speed, must be used to determine actual operating speeds in stepped-advance label systems. C-GAGE SLC1 Series Label Sensor 4 www.bannerengineering.com - tel: 763-544-3164 P/N 59369 Rev. B |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |