| Electronic Components Datasheet Search |
|
KMA310 Datasheet(PDF) 43 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
KMA310 Datasheet(HTML) 43 Page - NXP Semiconductors |
|
43 / 71 page ![]() NXP Semiconductors KMA310 Programmable angle sensor IC KMA310 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2019. All rights reserved. Product data sheet Rev. 3 — 27 February 2019 43 / 71 16.3.2 Read access To read data from the sensor, perform the following procedure: 1. Start condition: The master drives a rising edge after a LOW level 2. Command: The master sends a read command (CMD0 = 1) 3. Handover: The master sends a handover bit that is a logic 0 and disables the output after a three-quarter bit period 4. Takeover: The slave drives a LOW level after the falling edge for ttko(slv) 5. Data: The slave sends two data bytes 6. Handover: The slave sends a handover bit that is a logic 0 and disables the output after a three-quarter bit period 7. Takeover: The master drives a LOW level after the falling edge for ttko(mas) 8. Stop condition: The master drives a rising edge after a LOW level Figure 25 shows the read access of the digital interface. The signal OWI represents the data on the bus from the master or slave. The signals: master output enable and slave output enable indicate when the master or the slave output is enabled or disabled, respectively. 001aag744 master output enable slave output enable START CMD7 CMD0 RDATA0 (1) (2) (2) (4) (5) (3) HANDSHAKE HANDSHAKE RDATA15 IDLE STOP OWI 1. Duration of LOW level for slave takeover ttko(slv). 2. The master output enable and the slave output enable overlap, because both drive a LOW level. However this behavior ensures the independency from having a pull-up or pull-down on the bus. In addition, it improves the EMC robustness, because all levels are actively driven. 3. Duration of LOW level for master takeover ttko(mas). 4. If the master does not take over, the pull-up generates the stop condition. Otherwise a timeout is generated if there is a pull-down and the slave waits for a rising edge as start condition. 5. If the master does not drive the bus, the bus-pull defines the bus. Figure 25. OWI read access |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |