OPA863 Datasheet(PDF) 17 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
OPA863 Datasheet(HTML) 17 Page - Texas Instruments |
|
17 / 24 page ![]() DAC8801 + ± I OUT R FB V REF V DD +6V -6V OP Ax863 V OU T TR X1 + ± OP Ax863 12 V R ISO + ± R F R G C G C Filt C AC2 R¶ R¶ 3.3 V PGA ADC MSP430FR6043 OP Ax863 TR X2 Processor Transmitter Receiver Receiver Transmitter NODE-1 NODE-2 3.3 V 12 V 0 V 12 V V TX 0 V 12 V V TX V R X V R X t 12 t 21 R R C AC1 12 V 17 OPA2863 www.ti.com SBOS982A – JUNE 2020 – REVISED JUNE 2020 Product Folder Links: OPA2863 Submit Documentation Feedback Copyright © 2020, Texas Instruments Incorporated 9.6 Clamp-On Ultrasonic Flow Meter Ultrasonic flow meters measure rate of flow of a liquid using transit-time difference, t12–t21 in Figure 17 which changes with and used to determine the flow rate. Figure 17 shows a representative schematic for a non- intrusive ultrasonic flow meter using the OPAx863 devices and 12-V transducer excitation. For the forward path, the OPAx863 devices are used as a unity-gain buffer for 12-V pulsed transducer excitation at Node 1. At the same time, the receiver circuit at Node 2, also using the OPAx863 devices, first provides an AC-gain followed by a DC-level shift to lead to the PGA, ADC and processing within the MSP430 microcontroller. For the reverse path, Node 2 and Node 1 use similar transmit and receive circuits discussed above. The OPAx863 devices wide GBW of 50 MHz introduces minimal phase-delay and low-noise for superior flow rate measurement. In battery powered systems, the amplifier stays in power-down mode for a majority of the time, resulting in very small average system-level power consumption and prolonged battery lifetime with its 1.5 µA (maximum) power-down mode quiescent current. Since the transmit and receive signal chains are connected to the same point at the respective node transducers, the OPAx863 devices 12.6-V supply voltage capability enables 12-V transducer excitation capability with damage to the front-end and need for external switches to make a compact solution. This makes the OPAx863 devices suitable for flow measurements in large diameter pipes and non-intrusive flow meters. Figure 17. Non-Intrusive Ultrasonic Flow Meter 9.7 Variable Reference Generator Using MDAC High-speed amplifiers may be used as a voltage buffer at MDAC output to generate a fast settling variable reference voltage. Figure 18 shows a representative circuit using DAC8801 and OPAx863. Figure 18. Variable Reference Generator Using MDAC and OPAx863 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |