Back Button ADG5401F Datasheet HTML 24Page - Analog Devices ADG5401F Datasheet HTML 25Page - Analog Devices ADG5401F Datasheet HTML 26Page - Analog Devices ADG5401F Datasheet HTML 27Page - Analog Devices ADG5401F Datasheet HTML 28Page - Analog Devices ADG5401F Datasheet HTML 29Page - Analog Devices ADG5401F Datasheet HTML 30Page - Analog Devices ADG5401F Datasheet HTML 31Page - Analog Devices ADG5401F Datasheet HTML 32Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 30 / 32 page
background image
ADG5401F
Data Sheet
Rev. 0 | Page 30 of 32
INTELLIGENT FAULT DETECTION
The ADG5401F digital output pin (FF) can interface with a
microprocessor or control system and be used as an interrupt
flag. This feature provides real-time diagnostic information on
the state of the device and the system to which the device connects.
The control system can use the digital interrupt to start a
variety of actions, such as the following:
•
Initiating investigation into the source of the overvoltage fault
•
Shutting down critical systems in response to the overvoltage
•
Data recorders marking data during these events as
unreliable or out of specification
For systems that are sensitive during a start-up sequence, the
active low operation of the flag allows the system to ensure that
the ADG5401F powers on and that all input voltages are within
the normal operating range before initiating operation.
The FF pin is an open drain that requires an external pull-up
resistor, which allows signals to be combined into a single
interrupt for larger modules that contain multiple devices.
LARGE VOLTAGE, HIGH FREQUENCY SIGNALS
Figure 28 illustrates the voltage range and frequencies that the
ADG5401F can reliably convey. For signals that extend across
the full signal range from VSS to VDD − 2 V, keep the frequency
below 2.5 MHz. If the required frequency is greater than
2.5 MHz, decrease the signal range appropriately to ensure
signal integrity.
AMPLIFIER OR DAC OUTPUT PROTECTION
The ADG5401F has a secondary feedback channel for protecting
the amplifier outputs or DAC outputs. The feedback channel
is connected between the drain feedback pin (DFB) and the
source feedback pin (SFB). This feedback channel has a typical
resistance of 0.6 kΩ and can close the feedback loop of an
amplifier output or a DAC output (see Figure 48). This
feedback loop removes any output error caused by the
main channel on resistance.
S
POC
VOUT/IOUT
D
IN
ADG5401F
FF
SFB
DFB
ADA4625-1
SECONDARY FEEDBACK CHANNEL
Figure 48. Amplifier Output Protection
The secondary feedback channel is also protected from over-
voltages to ±60 V and is controlled by the same switch driver
as the main switch channel. If a fault is detected on either the
source (S) or source feedback (SFB) pin, both the main switch
channel and the feedback channel open, protecting both the
amplifier output node and the negative input of the amplifier.
For optimal performance, it is recommended to keep the
maximum voltage differential between the S and SFB pins
to less than 1 V.
If the secondary feedback channel is not required, it is recom-
mended to short the S pin to the SFB pin and the D pin to the
DFB pin.
OPEN-LOOP PREVENTION
The open-loop prevention feature is an internal switch in the
ADG5401F. When the main switch is disabled, this switch
connects the drain (D) of the main switch and the drain of the
feedback switch (DFB) (see Figure 49). This internal open-loop
prevention switch opens and closes automatically when the
main channel switch toggles. This feature stabilizes an amplifier
output by preventing the amplifier from going into an open-
loop configuration. When the main switch disables in normal
operation or in a fault condition, the open-loop prevention
switch activates. Note that the open-loop prevention switch is
identical to the feedback channel switch.
S
VOUT/IOUT
D
ADG5401F
AD5423
SFB
DFB
1kΩ FEEDBACK CHANNEL
FOR DAC/AMP APPLICATIONS
OPEN-LOOP
PREVENTION SWITCH
VIOUT
+VSENSE
Figure 49. Open-Loop Prevention Feature



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com