| Electronic Components Datasheet Search |
|
DRV8955PRGER Datasheet(PDF) 21 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
DRV8955PRGER Datasheet(HTML) 21 Page - Texas Instruments |
|
21 / 45 page ![]() operation resumes (motor-driver operation and nFAULT released) when the VM undervoltage condition is removed. 7.3.6.2 VCP Undervoltage Lockout (CPUV) If at any time the voltage on the VCP pin falls below the CPUV voltage, all the outputs are disabled, and the nFAULT pin is driven low. The charge pump remains active during this condition. Normal operation resumes (motor-driver operation and nFAULT released) when the VCP undervoltage condition is removed. 7.3.6.3 Overcurrent Protection (OCP) An analog current-limit circuit on each FET limits the current through the FET by removing the gate drive. If this current limit persists for longer than the tOCP time, the half-bridge in which OCP is detected is disabled and the nFAULT pin is driven low. The charge pump remains active during this condition. Once the OCP condition is removed, normal operation resumes after applying an nSLEEP reset pulse or a power cycling. 7.3.6.4 Thermal Shutdown (OTSD) If the die temperature exceeds the thermal shutdown limit (TOTSD) all MOSFETs in the H-bridge are disabled, and the nFAULT pin is driven low. After the junction temperature falls below the overtemperature threshold limit minus the hysteresis (TOTSD – THYS_OTSD), normal operation resumes after applying an nSLEEP reset pulse or a power cycling. Fault Condition Summary Table 7-7. Fault Condition Summary FAULT CONDITION ERROR REPORT HALF- BRIDGE CHARGE PUMP LOGIC RECOVERY VM undervoltage (UVLO) VM < VUVLO nFAULT All Disabled Disabled Reset (VDVDD < 3.9 V) Automatic: VM > VUVLO CP undervoltage (CPUV) VCP < VCPUV nFAULT All Disabled Operating Operating VCP > VCPUV Overcurrent (OCP) IOUT > IOCP nFAULT Half-bridge with OCP is Disabled Operating Operating Latched Thermal Shutdown (OTSD) TJ > TTSD nFAULT All Disabled Disabled Operating Latched 7.4 Device Functional Modes 7.4.1 Sleep Mode (nSLEEP = 0) The state of the device is managed by the nSLEEP pin. When the nSLEEP pin is low, the device enters a low- power sleep mode. In sleep mode, all the internal MOSFETs are disabled and the charge pump is disabled. The tSLEEP time must elapse after a falling edge on the nSLEEP pin before the device enters sleep mode. The device is brought out of sleep automatically if the nSLEEP pin is brought high. The tWAKE time must elapse before the device is ready for inputs. 7.4.2 Operating Mode (nSLEEP = 1) When the nSLEEP pin is high, and VM > UVLO, the device enters the active mode. The tWAKE time must elapse before the device is ready for inputs. 7.4.3 nSLEEP Reset Pulse A latched fault can be cleared through a quick nSLEEP pulse. This pulse width must be greater than 20 µs and shorter than 40 µs. If nSLEEP is low for longer than 40 µs, but less than 120 µs, the faults are cleared and the device may or may not shutdown, as shown in the timing diagram (see Figure 7-14). This reset pulse does not affect the status of the charge pump or other functional blocks. www.ti.com DRV8955 SLOSE71 – APRIL 2020 – REVISED DECEMBER 2020 Copyright © 2020 Texas Instruments Incorporated Submit Document Feedback 21 Product Folder Links: DRV8955 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |