| Electronic Components Datasheet Search |
|
MAX17823BGCV Datasheet(PDF) 17 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX17823BGCV Datasheet(HTML) 17 Page - Maxim Integrated Products |
|
17 / 121 page ![]() ________________________________________________________________________________________________________________________________________________________________ MAX17823B 12-Channel High-Voltage Data Acquisition System www.maximintegrated.com Maxim Integrated | 17 Data Conventions Representation of data follows the conventions shown in Table 2. All registers are 16-bit words. Table 2. Numeric Conventions Description Convention Example Binary number 0b prefix 0b01100001 = 61h Hexadecimal address 0x prefix 0x61 Hexadecimal data h suffix 61h Register bit Register name [x] STATUS[15] = 1 Register field Field name [x:y] DA[4:0] = 0b01100 = 0Ch Concatenated numbers {xxxx, yyyy} {DA[4:0], 0b001} = 61h Data Acquisition A data acquisition is composed of the distinct processes defined in Table 3 and controlled by various configuration registers described in this section. Configuration changes should be made prior to the acquisition in which the changes are to be effected. Table 3. Data Acquisition Processes Process Description Conversion The ADC samples a single input channel, converts it into a 12-bit binary value, and stores it in an ALU register. Scan The ADC sequentially performs conversions on all enabled cell input channels. Measurement cycle or Sample The ADC performs two scans for the purpose of minimizing error. The conversions (two for each input channel) are averaged together to form a single 14-bit binary value called a measurement. Note: The auxiliary inputs are only scanned once to create the auxiliary measurements. Acquisition or Acquisition mode If oversampling is enabled, the ADC takes sequential measurements and averages them together to form one 14-bit binary value for each input channel sampled. If there is no oversampling, the acquisition is essentially a single measurement cycle. Note: The auxiliary inputs are never oversampled and are stored as 12-bit values. Precision Internal Voltage References The measurement system uses two precision, temperature-compensated voltage references. The references are completely internal to the device and do not require any external components. The primary voltage reference, or REF, is used to derive the linear regulator output voltage and to supply the ADC reference. An alternate, independent reference, ALTREF, may be used to verify the primary reference voltage as described in the Diagnostics section. Measurement Calibration The acquisition system is calibrated at the factory and cannot be changed afterwards. The calibration parameters are stored in a ROM consisting of 12 read-only registers, CAL0 – CAL10 and CAL15. ROMCRC[8:0] is an 8-bit CRC value based on the calibration ROM and is stored in ID2[15:8] at the factory. ROMCRC[8:0] may be used to check the integrity of the calibration as described in the Diagnostics section. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |