| Electronic Components Datasheet Search |
|
ABC401 Datasheet(PDF) 7 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
ABC401 Datasheet(HTML) 7 Page - Bel Fuse Inc. |
|
7 / 14 page ![]() ABC401 Series 7 Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD.01060_B PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Input Under Voltage Lockout Auto recovery, Hiccup Mode 60 75 - VAC Input Fuse 2x Time Lag 6.3 A, 250 V on L1 and L2 - - 6.3 A Over Current At nominal input voltages. V1: Hiccup mode, auto-recovering. V2: PTC limiting, auto-recovering. 5 VSB: Hiccup mode, auto-recovering. 110 - 150 %I1MAX Short Circuit At nominal input voltages. V1: Hiccup mode, auto-recovering. V2: PTC limiting, auto-recovering 5 VSB: Hiccup mode, auto-recovering. - - - Over Voltage 12 V 24 V 28 V 36 V 48 V 5 VSB Unit shut down and latch off 110 - 136 %VNOM Over Temperature (on primary stage) Shut down, latch off. - - - Over Temperature (on secondary side) Hiccup mode, auto-recovering. - - - Isolation Primary-to- Secondary Reinforced 4000 - - VAC Isolation Input-to-PE Basic 1500 VAC Isolation V1-to-V2 100 - - VDC Isolation Output-to-PE Basic 1500 - - VAC PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Operating Temperature Range No de-rating up to 50 °C PS starts up at -30 °C -20 - 50 °C De-rated Operating Temperature Range Natural convection cooling: Linearly de-rate from 250 W at 50 °C, to 100 W at 70 °C Forced air cooling: Linearly de-rate from 400 W at 50 °C, to 280 W at 70 °C. See graphs below. - - 70 °C Storage Temperature Range -40 - 85 °C Humidity RH, Non-condensing Operating Non-operating - - 90 95 % % Operating Altitude - - 4000 m Shock EN 60068-2-27 Operating: Half sine, 30 g, 18 ms, 3 axes, 6x each (3 positive and 3 negative). Non-Operating: Half sine, 50 g, 11 ms, 3 axes, 6x each (3 positive and 3 negative). Vibration EN 60068-2-64 Operating: Sine,10 – 500 Hz, 1 g, 3 axes, 1 oct/min., 60 min. Random, 5 – 500 Hz, 0.02 g 2/Hz, 1 g RMS, 3 axes, 30 min. Non-Operating: 5 – 500 Hz, 2.46 gRMS (0.0122 g 2/Hz), 3 axes, 30 min. MTBF Full Load, 120 VAC, 40 °C ambient 80% Duty cycle, Telcordia SR-332 Issue 2 400000 - - Hours Useful Life Low line range, 200 W, 40 °C ambient, natural convention. - 4 - Years Thermal Considerations The output power de-rating curves are herein provided. These curves can be used as a guideline to assess the limit in performance of a power supply once installed in a system providing controlled air flow at a certain input voltage and ambient temperature. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |