| Electronic Components Datasheet Search |
|
LTC4366 Datasheet(PDF) 17 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTC4366 Datasheet(HTML) 17 Page - Analog Devices |
|
17 / 22 page ![]() LTC4249 17 Rev. 0 For more information www.analog.com When the load is resistive, the calculation for ROV is unchanged. For VOUT = 48V and IOC = 732mA, ROV remains 1MΩ. However, the calculation for OV threshold must include an additional contribution from IMON output current due to the excess voltage over the resistive load: VOV =1.2V• 1 RIMON + 1 ROV IOUT •GIMON VOUT + 1 ROV where IOUT is the nominal load of 650mA yielding a result of VOV = 51.48V. To regain a higher OV threshold, ROV must increase, which will cause IOC to increase. For exam- ple, if ROV is increased to 1.21MΩ, VOV becomes 55.48V and IOC increases to 813mA. Reverse Current Circuit Breaker In applications where the ECB output (load side) could be pulled above the input, such as a power mux circuit, the risk of forward biasing the ECB body diode and conduct- ing current to the input exists. To overcome that possibil- ity, the two LTC4249 channels can be connected back to back as shown in Figure 19. The back to back connection places the two ECB body diodes in opposite directions and prevents current from the load connection at IN2 back to IN1, when the ECBs are off. When the channels are turned on, however, current can still pass through the ECBs in both directions. Fortunately, due to the reverse connection of channel 2, current from IN2 to OUT2 is still reported at IMON2 because channel 2 is operating normally if IN2 rises above OUT2. With an appropriate choice of RIMON2, an accurate “reverse cur- rent” threshold can be chosen to shut off channel 2 and prevent excess current from the load connection at IN2 back to IN1. Channel 1 operates as usual and turns off due to excess forward current, configured by RIMON1. TO LOAD 6V TO 65V RIMON1 10F CLOAD GND IN1 OUT1 EN1 RDY1 LTC4249 IMON1 IMON2 RDY2 IN2 EN2 OUT2 INTVCC 0.1F C1 SOME CONNECTIONS OMITTED FOR CLARITY ENABLE RIMON2 4249 F19 Figure 19. Back to Back Connection for Load Isolation and Forward/Reverse Current Circuit Breaker Load Switch with Isolation Building from Figure 19, a load switch with reverse isola- tion is possible by duplicating the application and provid- ing enable inputs to preferentially select the input supply (V1 or V2) that is delivered to the load (Figure 20). APPLICATIONS INFORMATION |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |