MSM60808 Datasheet(HTML) 79 Page - OKI electronic componets |
|
79 / 92 page ![]() 79 ¡ Semiconductor MSM60808 5.3.6 CardBus Clock Control Register (CLKCTL) This register is used to control the CardBus clock. Offset : 20h Default value : 0000 0000h Access : Read-only Size : 32-bit 1 0 Start Clock Disable Stop Clock Reserved (0) 31~2 Bit Description These reserved bits always read 0. Bit [31:2] When the Start Clock Disable bit is 0, CCLK will be output on the CardBus and CCLKRUN# will be asserted. If this bit is set to 1, then the clock supply to the CardBus will stop when CCLKRUN# from the CardBus is not asserted. Bit 1 When the Clock Stop bit is set to 1, the MSM60808 will drive CCLKRUN# high. Then the clock will stop after 4 clocks. Bit 0 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|