3 / 23 page ![]() www.sensirion.com Version 3 – August 2020 3/23 1 Humidity and Temperature Sensor Specifications Relative Humidity Parameter Conditions Value Units Accuracy tolerance2 Typ. 1.5 %RH Max. see Figure 1 - Repeatability3 Low, typ. 0.21 %RH Medium, typ. 0.15 %RH High, typ. 0.08 %RH Resolution Typ. 0.01 %RH Hysteresis At 25°C 0.8 %RH Specified range4 Non-condensing environment5 0 to 100 %RH Response time6 63% 87 s Long-term drift8 Typ. <0.25 %RH/y Table 1: Humidity sensor specifications Temperature Parameter Conditions Value Units Accuracy tolerance1 Typ., 20°C to 50 °C 0.1 °C Max. see Figure 2 - Repeatability3 Low, typ. 0.15 °C Medium, typ. 0.08 °C High, typ. 0.04 °C Resolution Typ. 0.01 °C Operating range - –40 to 1059 °C Response time10 63% >2 s Long-term drift Max. <0.03 °C/y Table 2: Temperature sensor specifications 2 For definition of typ. and max. accuracy tolerance, please refer to the document “Sensirion Humidity Sensor Specification Statement”. 3 The stated repeatability is 3 times the standard deviation (3σ) of multiple consecutive measurement values at constant conditions and is a measure for the noise on the physical sensor output. 4 Specified range refers to the range for which the humidity sensor specification is guaranteed. 5 Condensation shall be avoided because of risk of corrosion and leak currents on the PCB. For details about recommended humidity and temperature operating range, please refer to Section 1.2. 6 Time for achieving 63% of a humidity step function, valid at 25°C and 1 m/s airflow. Humidity response time in the application depends on the design-in of the sensor. 7 With activated ART function (see Section 4.8) the response time can be improved by a factor of 2. 8 Typical value for operation in normal RH/T operating range. Max. value is < 0.5 %RH/y. Value may be higher in environments with vaporized solvents, out-gassing tapes, adhesives, packaging materials, etc. For more details please refer to Handling Instructions. 9 All parts, incl. PCB are rated up to 125°C, except for the connector, which is rated for 105°C. 10 Temperature response time depends on heat conductivity of sensor substrate and design-in of sensor in application. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |