Back Button OPA593 Datasheet HTML 6Page - Texas Instruments OPA593 Datasheet HTML 7Page - Texas Instruments OPA593 Datasheet HTML 8Page - Texas Instruments OPA593 Datasheet HTML 9Page - Texas Instruments OPA593 Datasheet HTML 10Page - Texas Instruments OPA593 Datasheet HTML 11Page - Texas Instruments OPA593 Datasheet HTML 12Page - Texas Instruments OPA593 Datasheet HTML 13Page - Texas Instruments OPA593 Datasheet HTML 14Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 23 page
background image
The current limit of the OPA593 has a ±10% tolerance for output currents between 25 mA and 50 mA, and
is ±5% accurate for currents ≥ 50 mA. Any resistor or DAC tolerances add to the OPA593 tolerance, so take
care when selecting the external components to make sure and provide the desired system level accuracy. A
correlation between the ideal or calculated output current limit and the actual current limit as measured on the
OPA593 is shown in Figure 7-2.
Current Limit Resistor (k )
0
25
50
75
100
125
150
175
200
225
250
-300
-250
-200
-150
-100
-50
0
50
100
150
200
250
300
Ideal ILIMIT Sourcing
Measured ILIMIT Sourcing
Ideal ILIMIT Sinking
Measured ILIMIT Sinking
Figure 7-2. Output Current vs Current-Limit Resistor Configuration
7.3.2 Overcurrent Flag
The OPA593 features an overcurrent flag to indicate a condition where the output current draw attempts to
exceed the limit configured through the ILIMIT pin, such as in a output short to ground fault condition. In such
a situation, the internal current limit of the amplifier limits the output current to the configured value and the flag
trips. This flag is an open-drain output designed to connect to standard low-voltage logic circuitry, such as a
microcontroller (MCU).
7.3.3 Overtemperature Flag
The OPA593 features an internal thermal shutdown feature. The op amp output stage disables when the junction
temperature reaches 170°C. After the junction temperature cools to 150°C, the output stage is enabled, and the
op amp resumes normal operation. In the event of an overtemperature condition a thermal flag trips. This flag is
an open-drain output designed to connect to standard low-voltage logic circuitry, such as an MCU.
OPA593
SBOS659A – JANUARY 2022 – REVISED MARCH 2022
www.ti.com
10
Submit Document Feedback
Copyright © 2022 Texas Instruments Incorporated
Product Folder Links: OPA593



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com