0900236 Datasheet(PDF) 3 Page - PHOENIX CONTACT |
|
|
|||||||||||||||||||||||||||||
0900236 Datasheet(HTML) 3 Page - PHOENIX CONTACT |
|
3 / 10 page ![]() ECP-E2... 102899_en_03 PHOENIX CONTACT 3 3 Technical data Operating data Nominal voltage 24 V DC DC supply voltage 18 V DC ... 32 V DC Nominal current I N Depending on the selected item version: 1 A, 2 A, 3 A, 4 A, 6 A, 8 A, 10 A, 12 A Closed circuit current I 0 In the ON state: 20 mA ... 30 mA, typical (depending on the signal output) Tripping current (bimetal) 0.3 A, typical (only in the event of an error, until electrically shut down) Indication of the operating state – Multi-color LED – Floating signal contact F – On/off position of switch S1 Multi-color LED Green = Device switched on (S1 = ON) or load circuit/Power MOSFET controlled Orange = Overload or short circuit until electronically shut down Red = Device electronically shut down, load circuit/Power MOSFET switched off, undervoltage (U B < 8 V) or after switch-on until the end of the switch-on delay time OFF: Manually switched off (S1 = OFF) or device power supply disconnected Protection against polarity reversal of U B Internal bimetal (failsafe element) triggered, pushbutton moves to OFF position Auxiliary contacts Pin 11 (GND) Pin 12 (individual indication) Pin 13/14 (group query) Switching capacity I CN Active current limitation of 180% Load circuit Load output Power MOSFET output (positive switching) Overload shutdown 1.1 x I N (1.05 ... 1.35 x IN), typical Short circuit current I K Active current limitation; 1.8 x I N, maximum (see "Time-current characteristic" on page 6) Shutdown time 3 s at I L > 1.1 x IN, typical 100 ms ... 3 s at I L > 1.8 x IN (or 1.5 x IN/1.3 x IN), typical See "Voltage drop, current limitation, maximum load current" on page 4 R i when plugged in = 50 m Temperature shutdown Internal temperature monitoring with electronic shutdown Undervoltage monitoring of load output With hysteresis, no reset required: OFF at U B < 8 V Switch-on delay t Start 0.5 s, typical after each switch-on and after applying U B Load circuit shutdown Electronic shutdown after overload/short circuit Free running circuit External free-wheeling diode recommended on inductive load Parallel connection of multiple load outputs Not permitted Alarm output F, signal contact Electrical data Floating signal contact 30 V DC/0.5 A, maximum; 10 V/10 mA, minimum Normal state, LED lights up green U B present and switch S1 set to ON and no overload, no short circuit OFF state, LED OFF – Device switched off (switch S1 set to OFF) – Operating voltage U B not present Error state, LED lights up orange Overload condition > 1.1 x I N until electronically shut down Error state, LED lights up red – Electronic shutdown after overload or short circuit – Device switched off with control signal (switch S1 set to ON) – Group signal, N/O contact, contact SC-SO open Error pattern Alarm output F (signal contact) is in the error state if: – Operating voltage U B is not present – ON/OFF switch S1 is set to OFF – The LED lights up red (electronic shutdown) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |