1 / 10 page ![]() © PHOENIX CONTACT 2010-12-17 102899_en_03 CLIPLINE ECP-E2... Data sheet 1Description The ECP-E2… electronic circuit breaker can be used in applications that cover all aspects of the switched-mode power supply unit. In the event of an overload, switched-mode power supply units reduce their output voltage, which means that all the connected loads are no longer sufficiently supplied, e.g., in the event of a short circuit at the load. The solution here is the ECP-E2… electronic circuit breaker, which selectively protects all 24 V DC load circuits. The ECP-E2… constantly limits the residual current to 1.8 times (or 1.5/1.3 times) the protected nominal current. Capacitive loads can thus be switched on and loads are only switched off in the event of an overload or short circuit. In addition, the ECP-E2… can be controlled remotely by means of the control input (12), for example, via a PLC, i.e., the ECP-E2… is electronically connected by means of an external +24 V DC permanent signal (at connection 12), enabling current to flow in the load circuit. Defined shutdown, independent of the load, is carried out by applying the ground signal at the same control input (12). The floating auxiliary contacts of the ECP-E2… can be used to implement a group query from connection 13 to 14. If a circuit breaker trips or is disabled, the signal to connection 14 is interrupted. A multi-color LED and the signal contact indicate the operating or error state. 1.1 Properties – Selective load protection, electronic shutdown characteristic curve – Active current limitation when switching on capacitive loads up to 20,000 µF and in the event of overload/short circuit – Nominal current can be selected in fixed current strengths from 1 A ... 12 A – Safe overload shutdown from 1.1 x I N, even for long load cables or low cable cross-sections – Manual on/off switch (S1) – Control input IN+ for remote ON/OFF signal – Indication by means of LED or signal contact F – Integrated failsafe element – Design width of just 12.5 mm per channel – Can be plugged into a modular base NOTE: Make sure that the cable cross-section of the relevant load circuit is adapted to the nominal current of the ECP-E2… used. In the system or machine, take special precautionary measures to prevent system parts from restarting (according to Machinery Directive 2006/42/EC and EN 60204-1). In the event of an error (short circuit/overload), the load circuit is electronically shut down by the ECP-E2…. NOTE: Make sure that the cable cross-section of the relevant load circuit is adapted to the nominal current of the ECP-E2… used. Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page: Electronic circuit breaker |
Similar Part No. - 0900236 |
|
Similar Description - 0900236 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |