4 / 10 page ![]() ECP-E2... 102899_en_03 PHOENIX CONTACT 4 Control input IN+ Electrical data Maximum voltage +32 V DC High > 8 V DC ≤ 32 V DC Low ≤ 3 V DC > 0 V DC Current consumption 2.6 mA, typical (+24 V DC) Minimum pulse length 10 ms Control input IN+ (terminal block 12) +24 V level (HIGH): Device is switched on by a remote ON/OFF signal. 0 V level (LOW): Device is switched off by a remote ON/OFF signal. Switch S1 ON/OFF Device can only be switched on with S1 if a HIGH level is present at IN+. General data Width x length x height 12.5 mm x 60 mm x 70 mm Weight 40 g Service life at 1 x I N 10,000 Ambient temperature 0°C ... +50°C (no condensation, see EN 60204-1) Storage temperature -20°C ... +70°C Insulation material PA-F Inflammability class according to UL 94 V0 Backup fuse Not required, since a redundant failsafe element is integrated. If the failsafe element has been triggered, the pushbutton is in the OFF position. Housing fixing Can be plugged into TMCP SOCKET M modular base Slip-on connections 6.3 mm according to DIN 46244-A6.3-0.8 Humid heat 96 h/95% relative humidity/40°C according to IEC 60068-2-78, Test Cab climatic class 3K3 according to EN 60721 Degree of protection Housing: IP30, DIN 40050 Terminal blocks: IP00, DIN 40050 Tests/approvals Conformance with EMC Directive 2004/108/EC Noise emission: EN 61000-6-3 Noise immunity: EN 61000-6-2 Isolation coordination (IEC 60934) 0.5 kV/pollution degree 2, increased isolation in the actuation area Dielectric strength 32 V DC, maximum (load circuit) Insulation resistance (OFF state) None, electronic shutdown only Vibration resistance 3g, test according to IEC 60068-2-6 Test Fc Approvals u UL 2367, File E317172 Solid State Overcurrent Protectors c Voltage drop, current limitation, maximum load current Nominal current I N Typical voltage drop U ON at IN Active current limitation (typical) Maximum load current at 100% operating factor, T A = 40°C Maximum load current at 100% operating factor, T A = 50°C 1 A 80 mV 1.8 x I N 1 A 1 A 2 A 130 mV 1.8 x I N 2 A 2 A 3 A 80 mV 1.8 x I N 3 A 3 A 4 A 100 mV 1.8 x I N 4 A 4 A 6 A 130 mV 1.8 x I N 6 A 5 A 8 A 120 mV 1.5 x I N 8 A 7 A 10 A 150 mV 1.5 x I N 10 A 9 A 12 A 180 mV 1.3 x I N 12 A 10.8 A When mounted in rows without convection cooling, due to the thermal effect during continuous operation (100% operating factor) the nominal device current must only be led to a maximum of 80%. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |