Back Button NM95HS02EN Datasheet HTML 6Page - National Semiconductor (TI) NM95HS02EN Datasheet HTML 7Page - National Semiconductor (TI) NM95HS02EN Datasheet HTML 8Page - National Semiconductor (TI) NM95HS02EN Datasheet HTML 9Page - National Semiconductor (TI) NM95HS02EN Datasheet HTML 10Page - National Semiconductor (TI) NM95HS02EN Datasheet HTML 11Page - National Semiconductor (TI) NM95HS02EN Datasheet HTML 12Page - National Semiconductor (TI) NM95HS02EN Datasheet HTML 13Page - National Semiconductor (TI) NM95HS02EN Datasheet HTML 14Page - National Semiconductor (TI) Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 20 page
background image
Data Frame Fields (Continued)
TRANSMISSION INDICATION
Both the LED and RFEN signals can be used to indicate
HiSeC rolling code transmission The LED output is active
low during the transmission of a pause whereas the RFEN
output is active low during transmission of either a frame or
a pause Either output may be used to provide a visual indi-
cation of transmission by connecting an LED between VCC
and LED or RFEN
If the low battery detect option is enabled and the battery is
low the LED output is active only during the pause following
the first frame of a new code transmission It is not active on
successive pauses in order to conserve power
Operational Timing Issues
DATA FRAME PAUSE LENGTH
After the complete transmission of a data frame a pause is
inserted before the next data frame is transmitted The
pause length can be modifed by configuring the 2-bit Pause-
Length parameter in EEPR0M PauseLength is broken down
into two single bit parameters Pause1 and Pause0 Avail-
able configuration options are shown in Table III
TABLE III Pause Length Select Options
PAUSE1
PAUSE0
Function
Pause Time
00
0 c P3 Output
No Pause
01
8 c P3 Output
20 ms
10
20 c P3 Output
50 ms
11
50 c P3 Output
100 ms
HiSeC GENERATOR TIME-OUT
If
the
NM95HS0102
time-out
option
is
enabled
(TIMEOUTEN e 1) the device will enter halt mode 80 sec-
onds after a key is first activated regardless of whether the
key is still being pressed This option guards against the
condition that a key may be stuck low which could drain the
battery If TIMEOUTEN e 0 the generator will continue to
transmit data frames as long as a key is pressed
HiSeC GENERATOR TIMER BLOCK
Bit timing and several function operating times are set in the
generator through a user programmable timer block This
timer block is used to provide IR and RF bit timing signals
the interframe pause time the AutoResync timing period
and the time-out delay
The NM95HS0102 timer block consists of three program-
mable 6-bit prescalers and a fixed 16-bit prescaler The in-
put to Prescaler1 is
of the frequency of CKI The output is
the IR clock This signal becomes the input to Prescaler2
The output from Prescaler2 is the RF clock This signal then
becomes the input to Prescaler3 The output from Prescal-
er3 is a target value of 25 ms Finally this 25 ms timing
signal becomes the input to the fixed 16-bit prescaler There
are several outputs from this prescaler The 25 ms is divid-
ed by 4 4096 and 32768 and these times are used to set
the key debounce time (10 ms) the AutoResync time
(l10 sec) and the generator time-out period (l80 sec)
respectively
The NM95HS0102 timer block is shown in
Figure 8
The purpose of the prescalers is to provide various timing
signals to the state machines in the generator The IR clock
is used as a time base for the various IR bit coding formats
The RF clock is used for RF bit coding formats A program-
mable bit called SCLK determines whether the IR clock
(SCLK e 0) or the RF clock (SCLK e 1) is used as the bit
timing time base In addition to SCLK the system designer
can program Prescaler1 Prescaler2 and Prescaler3 sepa-
rately to set the necessary division factors Since each of
these prescalers is 6 bits permissible values range from 2
to 64
The system designer must set the programmable prescalers
to meet the necessary timing requirements for all the func-
tions discussed above All of these timings are interdepen-
dent
Figure 9 provides the basis for an example in calculating the
necessary timing for these functions and setting the timer
block appropriately
TLD12302 – 19
FIGURE 8 The NM95HS0102 Timer Block
TLD12302 – 20
FIGURE 9 NM95HS0102 Timer Block Example
http
www nationalcom
10



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com