12 / 26 page ![]() 8 Open-load In order to detect the open-load fault, a pull-up resistor must be connected between the VCC line and the output pin. In a normal condition, a current flows through the network made up of a pull-up resistor and a load. The voltage across the load is less than VOLMIN and the DIAG pin is kept high. This is the result in the condition: Equation 1: VCC [RLOAD / ( RLOAD + RPU )] < VOLMIN or Equation 2: [(VCC / VOLMIN) - 1] RLOAD < RPU When an open-load event occurs the voltage on the output pin rises to a value higher than VOLMAX (depending on the pull-up resistor) and the diag pin goes down. This is the result in the condition: Equation 3: RPU < (VCC - VOLMAX) / |IOUT(OFF1)MIN| Figure 8. Open-load detection VNI2140 Open-load DS5977 - Rev 11 page 12/26 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|