SP3244E Datasheet(PDF) 14 Page - Sipex Corporation |
|
|
|||||||||||||||||||||||||||||
SP3244E Datasheet(HTML) 14 Page - Sipex Corporation |
|
14 / 22 page ![]() Rev M 10/9/06 SP3244E-SP3245E, 3.0V to 5.5V RS-232 Transceivers with Auto On-Line® Plus © Copyright 2006 Sipex Corporation 14 ESD Test Conditions ESD performance depends on a variety of conditions. Contact Sipex for a reliability report that documents test setup, methodology and results. IEC 1000-4-2 The IEC 1000-4-2 standard covers ESD testing and performance of finished equip- ment. However, it does not specifically refer to integrated circuits. The SP3244E/3245E helps you design equipment to meet IEC 1000-4-2, without sacrificing boardspace and cost for external ESD-protection components. The major difference between tests done using the Human Body Model and IEC 1000-4-2 is a higher peak current in IEC 1000-4-2. DESCRIPTION Auto On-Line® Plus Truth Table Series resistance is lower in the IEC 1000-4-2 model. Hence, the ESD withstand voltage mea- sured to IEC 1000-4-2 is generally lower than that measured using the Human Body Model. The air-gap test involves approaching the device with a charged probe. The contact discharge method connects the probe to the device before the probe is energized. Machine Model The machine model for ESD tests all pins using a 200pF storage capacitor and zero discharge resistance. The objective is to emulate the stress caused when I/O pins are contacted by handling equipment during test and assembly. Device Pin Tested Human Body Model IEC1000-4-2 Air discharge Contact discharge Level TxOUT ± 15kV ± 15kV ± 8kV 4 RxIN ± 15kV ± 15kV ± 8kV 4 TxIN, RxOUT, ONLINE, SHUTDOWN, STATUS ± 2kV ± 2kV ± 2kV 1 Operating mode ONLINE SHUTDOWN |RxIN| > ± 2.7 V Idle inputs (RxIN & TxIN) TxOUT RxOUT R2OUT Forced Shutdown X 0 X X high-Z high-Z active Forced Online 1 1 X X active active active Auto On-line® Plus (Wake When Active) 0 1 X active active active active Auto On-line® Plus (Off-Line When Idle) 0 1 X idle > 30s high-Z active active Auto On-line® Plus (Wake On Cable) STATUS 1 yes X active active active Auto On-line® Plus (Wake When Active) STATUS 1 no active active active active Auto On-line® Plus (Off-Line When Idle) STATUS 1 no idle > 30s high-Z active active Auto On-line® (Wake On Cable) STATUS STATUS yes X active active active Auto On-line® (Auto Shutoff) STATUS STATUS no X high-Z active active ESD Table |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |