Back Button 74HC85 Datasheet HTML 5Page - Nexperia B.V. All rights reserved 74HC85 Datasheet HTML 6Page - Nexperia B.V. All rights reserved 74HC85 Datasheet HTML 7Page - Nexperia B.V. All rights reserved 74HC85 Datasheet HTML 8Page - Nexperia B.V. All rights reserved 74HC85 Datasheet HTML 9Page - Nexperia B.V. All rights reserved 74HC85 Datasheet HTML 10Page - Nexperia B.V. All rights reserved 74HC85 Datasheet HTML 11Page - Nexperia B.V. All rights reserved 74HC85 Datasheet HTML 12Page - Nexperia B.V. All rights reserved 74HC85 Datasheet HTML 13Page - Nexperia B.V. All rights reserved Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 17 page
background image
Nexperia
74HC85; 74HCT85
4-bit magnitude comparator
25 °C
-40 °C to
+85 °C
-40 °C to
+125 °C
Symbol Parameter
Conditions
Min
Typ
Max
Min
Max
Min
Max
Unit
74HCT85
An, Bn to QA>B;
An, Bn to QA<B; see Fig. 7
[1]
VCC = 4.5 V
-
26
44
-
55
-
66
ns
VCC = 5.0 V; CL = 15 pF
-
22
-
-
-
-
-
ns
An, Bn to QA=B; see Fig. 7
VCC = 4.5 V
-
24
40
-
50
-
60
ns
VCC = 5.0 V; CL = 15 pF
-
20
-
-
-
-
-
ns
IA=B or IA>B to QA<B;
IA<B or IA=B to QA>B;
see Fig. 7
VCC = 4.5 V
-
18
31
-
39
-
47
ns
VCC = 5.0 V; CL = 15 pF
-
15
-
-
-
-
-
ns
IA=B to QA=B; see Fig. 7
VCC = 4.5 V
-
18
31
-
39
-
47
ns
tpd
propagation
delay
VCC = 5.0 V; CL = 15 pF
-
15
-
-
-
-
-
ns
tt
transition time VCC = 4.5 V; see Fig. 7
[2]
-
7
15
-
19
-
22
ns
CPD
power
dissipation
capacitance
per package;
VI = GND to VCC - 1.5 V
[3]
-
20
-
-
-
-
-
pF
[1] tpd is the same as tPHL and tPLH.
[2] tt is the same as tTHL and tTLH.
[3] CPD is used to determine the dynamic power dissipation (PD in μW).
PD = CPD × VCC 2 × fi + Σ (CL × VCC 2 × fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
Σ (CL × VCC 2 × fo) = sum of outputs;
CL = output load capacitance in pF;
VCC = supply voltage in V.
74HC_HCT85
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2021. All rights reserved
Product data sheet
Rev. 4 — 4 August 2021
9 / 17



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com