MP6631 Datasheet(PDF) 13 Page - Monolithic Power Systems

Part # MP6631
Description  24V Input, 3A Peak Phase Current,Three-Phase BLDC Motor Driver
PDF  27 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MPS [Monolithic Power Systems]
Direct Link  http://www.monolithicpower.com
Logo MPS - Monolithic Power Systems

MP6631 Datasheet(HTML) 13 Page - Monolithic Power Systems

Back Button MP6631 Datasheet HTML 9Page - Monolithic Power Systems MP6631 Datasheet HTML 10Page - Monolithic Power Systems MP6631 Datasheet HTML 11Page - Monolithic Power Systems MP6631 Datasheet HTML 12Page - Monolithic Power Systems MP6631 Datasheet HTML 13Page - Monolithic Power Systems MP6631 Datasheet HTML 14Page - Monolithic Power Systems MP6631 Datasheet HTML 15Page - Monolithic Power Systems MP6631 Datasheet HTML 16Page - Monolithic Power Systems MP6631 Datasheet HTML 17Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 27 page
background image
MP6631 – 24V, 3A PEAK, THREE-PHASE BLDC MOTOR DRIVER
MP6631 Rev. 1.1
MonolithicPower.com
13
2/21/2023
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2023 MPS. All Rights Reserved.
Figure 6 shows the curve configuration when
SPD_ZERO = 0.
37.5% 50% 62.5% 75% 87.5% 100%
Input PWM duty
SPD_MIN
D37.5
D50
D62.5
D75
D87.5
SPD_MAX
Speed
Figure 6: Curve Configuration when
SPD_ZERO = 0
Speed Open-/Closed-Loop Control
In closed-loop mode (OPEN_L = 0, CLOSE_H
= 1), the MP6631 internally detects the Hall
signal speed and feedback to the control loop,
then adjusts the output PWM duty in a closed
loop. By doing this, the motor speed follows the
reference exactly.
In open-loop mode (OPEN = 1), the OUTA,
OUTB, and OUTC output duty cycles directly
depend on the PWM input duty.
In mixed mode (OPEN_L = 0, CLOSE_H = 0),
the MP6631 operates in closed-loop mode
when the PWM input duty is below 87.5%, and
operates in open-loop mode when input duty
exceeds 87.5%.
Soft-Start Time
To reduce the input inrush current during start-
up, the MP6631 provides the reference speed
’s
configurable soft-start time (tSS) by setting
register bits TDYN[1:0]. This time can be
configured from 1.3s to 10.4s.
Closed-Loop Integrator Gain
In closed-loop mode, the closed-loop integrator
gain depends on registers KI[7:0] and KP[7:0].
Higher KI and KP values lead to quick loop
response. KI and KP should be adjusted
according to the dynamic response and steady
state operation.
Single- or Triple-Hall Input Mode
The MP6631 supports either a single or triple
Hall-effect sensor. If a single Hall-effect sensor
is employed, the Hall selecting bit must set the
single Hall sensor, and Hall C is used as the
control.
Direction Control
The direction is controlled by the
DIR pin’s
polarity. When DIR is pulled low, the MP6631
operates in forward rotation in the following
sequence: A → B → C → A
…
When DIR is pulled high, the MP6631 operates
in reverse rotation in the following sequence: A
→ C → B → A...
Alignment
After VCC start-up, all MOSFETs remain off
until the fan speed drops below the threshold
speed or for a set time, determined by the
register setting.
In single Hall sensor applications, the MP6631
aligns the rotor in certain positions depending
on the Hall outputs. After the alignment time set
by register TOPS completes, the MP6631
enters pre-startup. This function is only enabled
in single Hall sensor applications.
Pre-Startup Timer
During
pre-startup,
the
MP6631
gradually
increases the output duty cycle with the timer
set by the TPRE[1:0] bits. This provides
sufficient torque for robust start-up and avoids
current overshoot during start-up.
• TPRE[1:0] = 0: Timer period is 2.5ms
• TPRE[1:0] = 1: Timer period is 5ms
• TPRE[1:0] = 2: Timer period is 10ms
• TPRE[1:0] = 3: Timer period is 20ms
A higher timer period leads to lower soft pre-
startup current, but increases pre-startup time.
Cycle-by-Cycle
Over-Current
Protection
(OCP)
During normal switching, if the current flowing
through the MOSFET exceeds the threshold set
by register bits OCP[1:0] after a set blanking
time, then the high-side MOSFETs (HS-FETs)
turn off and the low-side MOSFETs (LS-FETs)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com