| Electronic Components Datasheet Search |
|
WM8580 Datasheet(PDF) 49 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8580 Datasheet(HTML) 49 Page - Wolfson Microelectronics plc |
|
49 / 92 page ![]() Production Data WM8580 w PD Rev 4.0 February 2007 49 f2 TO PLLxCLK DIVISION FACTOR POSTSCALE_x FREQMODE_x[1:0] 0 1 00 ÷2 ÷4 01 ÷4 ÷8 10 ÷8 ÷16 11 ÷12 ÷24 Table 43 PLL User Mode Clock Divider Configuration POSTSCALE_A PLLACLK FREQUENCY 0 256fs 1 128fs Table 44 PLL S/PDIF Receiver Mode Clock Divider Configuration PLL CONFIGURATION EXAMPLE Consider the situation where the oscillator clock (OSCCLK) input frequency is fixed at 12MHz and the required PLLBCLK frequency is 12.288MHz. 1. Calculate the f2, FREQMODE_B and POSTSCALE_B Values The PLL is designed to operate with best performance when the f2 clock is between 90 and 100MHz. The necessary PLLBCLK frequency is 12.288MHz. Choose POSTSCALE_B and FREQMODE_B values to set the f2 frequency in the range of 90 to 100MHz. In this case, the default values (POSTSCALE_B = 0 and FREQMODE_B[1:0] = 10) will configure the f2 to PLLBCLK divider as 8 and hence will set the f2 frequency at 98.304MHz; this value is within the 90 to 100MHz range and is hence acceptable. • POSTSCALE_B = 0 • FREQMODE_B [1:0] = 10b • f2 = 98.304MHz 2. Calculate R Value Using the relationship: R = (f2 ÷ f1), the value of R can be calculated. • R = (f2 ÷ f1) • R = (98.304 ÷ 12) • R = 8.192 3. Calculate PLLB_N Value The value of PLLB_N is the integer (whole number) value of R, ignoring all digits to the right of the decimal point. In this case, R is 8.192, hence PLLB_N is 8. 4. Calculate PLL_K Value The PLLB_K value is simply the integer value of (222 (R-PLLB_N)). • PLLB_K = integer part of (222 x (8.192 – 8)) • PLLB_K = integer part of 805306.368 • PLLB_K = 805306 (decimal) / C49BA (hex) A number of example configurations are shown in Table 45. Many other configurations are possible; Table 45 shows only a small number of valid possibilities. As both PLLs are identical, the same configuration procedure applies for both. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |