14 / 24 page ![]() AD8315 Rev. C | Page 14 of 24 First, the summed detector currents are written as a function of the input IDET = ISLP log10 (VIN/VZ) (3) where: IDET is the partially filtered demodulated signal, whose exact average value is extracted through the subsequent integration step. ISLP is the current-mode slope and has a value of 115 μA per decade (that is, 5.75 μA/dB). VIN is the input in V rms. VZ is the effective intercept voltage, which, as previously noted, is dependent on waveform but is 316 μV rms (−70 dBV) for a sine wave input. Now the current generated by the setpoint interface is simply ISET(4) = VSET/415 kΩ (4) The difference between this current and IDET is applied to the loop filter capacitor CFLT. It follows that the voltage appearing on this capacitor, VFLT, is the time integral of the difference current: VFLT(s) = (ISET − IDET)/sCFLT (5) ( ) FLT Z IN SLP SET sC V V I V 10 log kΩ 4.15 − = (6) The control output VAPC is slightly greater than this, because the gain of the output buffer is ×1.35. In addition, an offset voltage is deliberately introduced in this stage; this is inconsequential because the integration function implicitly allows for an arbitrary constant to be added to the form of Equation 6. The polarity is such that VAPC rises to its maximum value for any value of VSET greater than the equivalent value of VIN. In practice, the VAPC output rails to the positive supply under this condition unless the control loop through the power amplifier is present. In other words, the AD8315 seeks to drive the RF power to its maximum value whenever it falls below the setpoint. The use of exact integration results in a final error that is theoretically 0, and the logarithmic detection law would ideally result in a constant response time following a step change of either the setpoint or the power level, if the power- amplifier control function were likewise linear in dB. However, this latter condition is rarely true, and it follows that in practice, the loop response time depends on the power level, and this effect can strongly influence the design of the control loop. Equation 6 can be restated as () ( ) sT V V V V s V Z IN SLP SET APC 10 log − = (7) where VSLP is the volts-per-decade slope from Equation 1, having a value of 480 mV/decade, and T is an effective time constant for the integration, being equal to 4.15 kΩ × CFLT/1.35; the resistor value comes from the setpoint interface scaling Equation 4 and the factor 1.35 arises because of the voltage gain of the buffer. Therefore, the integration time constant can be written as T = 3.07 CFLT in μs, when C is expressed in nF (8) To simplify our understanding of the control loop dynamics, begin by assuming that the power amplifier gain function is actually linear in dB, and for the moment, use voltages to express the signals at the power amplifier input and output. Let the RF output voltage be VPA and let its input be VCW. Furthermore, to characterize the gain control function, this form is used ( ) GBC APC V V CW O PA V G V 10 = (9) where: GO is the gain of the power amplifier when VAPC = 0. VGBC is the gain scaling. While few amplifiers conform so conveniently to this law, it provides a clearer starting point for understanding the more complex situation that arises when the gain control law is less ideal. This idealized control loop is shown in Figure 34. With some manipulation, it is found that the characteristic equation of this system is () ( ) ( ) O Z CW O GBC SLP GBC SET APC sT V V kG V V V V s V + − = 1 log 10 (10) where: k is the coupling factor from the output of the power amplifier to the input of the AD8315 (for example, ×0.1 for a 20 dB coupler). TO is a modified time constant (VGBC/VSLP)T. This is quite easy to interpret. First, it shows that a system of this sort exhibits a simple single-pole response, for any power level, with the customary exponential time domain form for either increasing or decreasing step polarities in the demand level VSET or the carrier input VCW. Second, it reveals that the final value of the control voltage VAPC is determined by several fixed factors: ( ) ( ) ( ) Z CW O SLP GBC SET APC V V kG V V V V 10 log τ − = ∞ = (11) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |