2 / 6 page ![]() 2 738A INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3ProgrammingOptions Use this section for reference when programming the module. INIT ALL? NO YES INITIALIZATION Select YES to reset all programming options to the factory default. Select NO to maintain all programming options at their current settings. BUS: *KYPD LX PANEL BUS TYPE Select the type of connection from the panel to the module. Choose either Keypad Bus or LX‑Bus connection. Press the CMD key to accept the selection. An asterisk displays to the left of the bus type selected. Note: If the 738A will be used on the keypad bus, ensure it is programmed as a device in Device Setup. HOUSE ID: 01 HOUSE ID Select a number from 01 to 31 for the House ID. Enter a leading zero for numbers less than ten. The factory default is 01. The same House ID number must be programmed into any 5804BD Wireless Key transmitters to receive Armed, Alarm, and Ready to Arm status. Refer to the Ademco 5804BD Installation Instructions to enter the House ID. ZONE? TEST ADD ZONE TEST OR ADD Select ADD to program new zones into the system or select TEST to perform a zone test on existing zones. When performing a Zone Test, the 5881 receiver signal gain is reduced by 50%. When adding new zones to the system, select TEST to perform the Zone Test. TRIPS END ZONE TEST TRIPS COUNTER When TEST is selected, the Zone Test Trips Counter displays the number of times any programmed zone trips (alarm/short) during the Zone Test. The keypad buzzer sounds for 1 second each time a programmed zone trips. Select END to stop the zone test and display any failed zones. Note: When the keypad is removed from the module, the 5881 receiver signal gain automatically returns to 100%. ZONE: XX ‑FAIL ZONE TEST FAIL The zone number of any zone that failed to trip at least once during the test displays for four seconds and the buzzer sounds for one second. The next failed zone displays. Press CMD to advance to the next failed zone. PROGRAM THE MODULE DMP BUS Ademco Reciever Model 738A PROG RECEIVER Model 330 Programming Harness PROGRAM 5800TM Transmitter To Keypad Bus or LX Bus Model 300 4-Wire Harness To Keypad DMP Model 300 Wire Color Ademco Harness Wire Color Red Red Yellow Yellow Green Green Black Black N/A Blue Figure 4: 738A Wiring |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |