10 / 17 page ![]() LM2596 /LM2596HV Series Buck Regulator Design Procedure (Adjustable Output) PROCEDURE (Adjustable Output Voltage Version) EXAMPLE (Adjustable Output Voltage Version) Given: V OUT = Regulated Output Voltage V IN(max) = Maximum Input Voltage I LOAD(max) = Maximum Load Current F = Switching Frequency (Fixed at a nominal 150 kHz). Given: V OUT = 20V V IN(max) = 28V I LOAD(max) = 3A F = Switching Frequency (Fixed at a nominal 150 kHz). 1. Programming Output Voltage (Selecting R 1 and R2,as shown in Figure 1 ) Use the following formula to select the appropriate resistor values. Select a value for R 1 between 240Ω and 1.5 kΩ. The lower resistor values minimize noise pickup in the sensitive feed- back pin. (For the lowest temperature coefficient and the best stability with time, use 1% metal film resistors.) 1. Programming Output Voltage (Selecting R 1 and R2,as shown in Figure 1 ) Select R 1 to be 1 kΩ, 1%. Solve for R2. R 2 = 1k (16.26 − 1) = 15.26k, closest 1% value is 15.4 kΩ. R 2 = 15.4 kΩ. 2. Inductor Selection (L1) A. Calculate the inductor Volt • microsecond constant E • T(V • µs), from the following formula: where V SAT = internal switch saturation voltage = 1.16V and V D = diode forward voltage drop = 0.5V B. Use the E • T value from the previous formula and match it with the E • T number on the vertical axis of the Inductor Value Selection Guide shown in Figure 7. C. on the horizontal axis, select the maximum load current. D. Identify the inductance region intersected by the E • T value and the Maximum Load Current value. Each region is identi- fied by an inductance value and an inductor code (LXX). E. Select an appropriate inductor from the four manufacturer’s part numbers listed in Figure 8. 2. Inductor Selection (L1) A. Calculate the inductor Volt • microsecond constant (E • T), B. E • T = 34.2 (V • µs) C. I LOAD(max) = 3A D. From the inductor value selection guide shown in Figure 7, the inductance region intersected by the 34 (V • µs) horizontal L39. E. From the table in Figure 8, locate line L39, and select an bers. 3A Step-Down Voltage Regulator UMW LM2596/LM2596HV UMW R UMW LM2596/LM2596HV UMW LM2596/LM2596HV 10 www.umw-ic.com 友台半导体有限公司 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |