Back Button PDIUSBD Datasheet HTML 2Page - NXP Semiconductors PDIUSBD Datasheet HTML 3Page - NXP Semiconductors PDIUSBD Datasheet HTML 4Page - NXP Semiconductors PDIUSBD Datasheet HTML 5Page - NXP Semiconductors PDIUSBD Datasheet HTML 6Page - NXP Semiconductors PDIUSBD Datasheet HTML 7Page - NXP Semiconductors PDIUSBD Datasheet HTML 8Page - NXP Semiconductors PDIUSBD Datasheet HTML 9Page - NXP Semiconductors PDIUSBD Datasheet HTML 10Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 20 page
background image
Philips Semiconductors
Product specification
PDIUSBD11
USB device with serial interface
1999 Jul 22
6
COMMAND SUMMARY
Some commands have the same command code (e.g., Read Buffer and Write Buffer). In these cases, the direction of the Data Phase (read or
write) indicates which command is executed.
COMMAND NAME
RECIPIENT
CODING
DATA PHASE
Initialization Commands
Set Address/Enable
Function
D1h
Write 1 byte
Set Endpoint Enable
Function
D8h
Write 1 byte
Set Mode
Function
F3h
Write 2 byte
Data Flow Commands
Read Interrupt Register
F4h
Read 2 bytes
Select Endpoint
Control OUT Endpoint
00h
Read 1 byte (optional)
Control IN Endpoint
01h
Read 1 byte (optional)
Other Endpoints
00h+Endpoint Index
Read 1 byte (optional)
Read Last Transaction Status
Control OUT Endpoint
40h
Read 1 byte
Control IN Endpoint
41h
Read 1 byte
Other Endpoints
40h+Endpoint Index
Read 1 byte
Read Endpoint Status
Control OUT Endpoint
80h
Read 1 byte
Control IN Endpoint
81h
Read 1 byte
Other Endpoints
80h+Endpoint Index
Read 1 byte
Read Buffer
Selected Endpoint
F0h
Read n bytes
Write Buffer
Selected Endpoint
F0h
Write n bytes
Set Endpoint Status
Control OUT Endpoint
40h
Write 1 byte
Set Endpoint Status
Control IN Endpoint
41h
Write 1 byte
Other Endpoints
40h+Endpoint Index
Write 1 byte
Acknowledge Setup
Selected Endpoint
F1h
None
Clear Buffer
Selected Endpoint
F2h
None
Validate Buffer
Selected Endpoint
FAh
None
General Commands
Send Resume
F6h
None
Read Current Frame Number
F5h
Read 1 or 2 bytes



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com