11 / 18 page  - 11 - © Andigilog, Inc. 2006 www.andigilog.com December 2006 - 70A05012 aSC7531A / aSC7531B Reserved or Unsupported Commands Attempts to access the sensor using a reserved or unsupported command will not result in the device or bus failure. The sensor will return a modified FCS when any of the following commands are received. To modify the FCS the sensor will invert all of the bits in the correct FCS (1’s complement). A modified FCS is also called an Abort FCS. The sensor will return an Abort FCS (modified FCS) for a reserved and unsupported command code (commands codes between 0xE4 to 0xF5 and 0xF8 to 0xFF). The sensor will return an Abort FCS (modified FCS) for reserved commands (command codes 0x02 to 0x0F and 0x15 to 0xDF). The sensor will return an Abort FCS (modified FCS) for unused vendor specific test and manufacturing command codes (command codes 0xE8 to 0xEF). If any of these types of commands exist, they will be disabled during normal operation. Malformed Commands A malformed command is one which is valid but has an incorrect write or read length for the given command. If a get temperature or get voltage command with a write length not equal to 1 is sent, then the aSC7531 will send an Abort FCS and wait for a new command. An Abort FCS will be formed by creating a 1’s complement of the good FCS. If a get temperature or get voltage command and the read length is not equal to 2, 4, or 10 then the aSC7531 will send an Abort FCS and wait for a stop on the SST bus. See the Command Summary section for the expected Write and Read lengths of the legal commands. There will be no checking for malformed WriteReg() and ReadReg() commands (Vendor Specific Extensions). Command Summary Hex Cmd Command Name Received Bytes Wr Len Rd Len Bytes Sent by Client - Ping() 3(target,wr,rd) 0 0 FCS 0x00 GetIntTemp() 4(target,wr,rd,cmd) 1 2 FCS/2/FCS 0x01 GetExtTemp() 4(target,wr,rd,cmd) 1 2 FCS/2/FCS 0x00 GetAllTemps() 4(target,wr,rd,cmd) 1 4 FCS/4/FCS 0x02-0x0F Unsupported Abort FCS 0x10 GetVolt12V() 4(target,wr,rd,cmd) 1 2 FCS/2/FCS 0x11 GetVolt5V() 4(target,wr,rd,cmd) 1 2 FCS/2/FCS 0x12 GetVolt3p3V() 4(target,wr,rd,cmd) 1 2 FCS/2/FCS 0x13 GetVolt2p5V() 4(target,wr,rd,cmd) 1 2 FCS/2/FCS 0x14 GetVoltVccp() 4(target,wr,rd,cmd) 1 2 FCS/2/FCS 0x10 GetAllVoltages() 4(target,wr,rd,cmd) 1 10 FCS/10/FCS 0x15-0xDF Unsupported Abort FCS 0xE0 WriteReg() 4(target,wr,rd,cmd) 3+ 0 FCS 0xE1 ReadReg() 4(target,wr,rd,cmd) 2 1+ FCS/1+/FCS 0xE2 VenCmdEnable() 4(target,wr,rd,cmd) 1 0 FCS 0xE3 VenCmdDisable() 4(target,wr,rd,cmd) 1 0 FCS 0xE4-0xF5 Unsupported Abort FCS 0xF6 ResetDevice() 4(target,wr,rd,cmd) 1 0 FCS 0xF6 ResetDevice() 4(target,wr,rd,cmd) 1 0 None if default address (0x00) 0xF7 GetDIB() 4(target,wr,rd,cmd) 1 8 FCS/8/FCS 0xF7 GetDIB() 4(target,wr,rd,cmd) 1 16 FCS/16/FCS 0xF8-0xFF Unsupported Abort FCS Table 4. Command Summary |
|