EPR-91 Datasheet(PDF) 19 Page - Power Integrations, Inc.

Part # EPR-91
Description  Engineering Prototype Report for EP-91 - 12 W Power Supply using
PDF  36 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  POWERINT [Power Integrations, Inc.]
Direct Link  http://www.powerint.com
Logo POWERINT - Power Integrations, Inc.

EPR-91 Datasheet(HTML) 19 Page - Power Integrations, Inc.

Back Button EPR-91 Datasheet HTML 15Page - Power Integrations, Inc. EPR-91 Datasheet HTML 16Page - Power Integrations, Inc. EPR-91 Datasheet HTML 17Page - Power Integrations, Inc. EPR-91 Datasheet HTML 18Page - Power Integrations, Inc. EPR-91 Datasheet HTML 19Page - Power Integrations, Inc. EPR-91 Datasheet HTML 20Page - Power Integrations, Inc. EPR-91 Datasheet HTML 21Page - Power Integrations, Inc. EPR-91 Datasheet HTML 22Page - Power Integrations, Inc. EPR-91 Datasheet HTML 23Page - Power Integrations, Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 19 / 36 page
background image
7-Feb-2006
EP-91 12 V, 1 A, Universal Input Supply
Page 19 of 36
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
9.2
Active Mode CEC Measurement Data
In the state of California, after July 1, 2006, all single-output EPS adapters – including
those sold with the products they power – must meet the California Energy Commission
(CEC) requirement for minimum active-mode efficiency and no-load input power
consumption. Minimum active-mode efficiency is defined as the average efficiency at 25,
50, 75 and 100% of rated output power printed on the nameplate of the supply:
Nameplate
Output (PO)
Minimum Efficiency in Active Mode
of Operation
< 1 W
0.49
× PO
≥ 1 W to ≤ 49 W
0.09
× ln (PO) + 0.49 [ln = natural log]
> 49 W
0.84 W
For adapters that are single input voltage only, the measurements are to be made at the
nominal rated input voltage (115 VAC or 230 VAC). For universal input adapters, the
measurements are to be made at both nominal input voltages (115 VAC and 230 VAC).
To comply with the standard, the average of the four efficiency measurements must be
greater than or equal to the efficiency specified by the standard.
Percent of Full
Load
Efficiency (%)
115 VAC
230 VAC
25
75
74.5
50
78.5
78.8
75
78.8
78.5
100
78
79.1
Average
77.6
77.7
Required CEC
minimum average
efficiency (%)
71.3
From these results it is apparent that the efficiency of this design easily exceeds the
required 71.3 %. More states within the USA, and many other countries around the world
are adopting similar energy efficiency standards (based on the original Energy Star
standard). For the latest, up-to-date information on energy efficiency regulations, please
visit the PI Green Room, at:
http://www.powerint.com/greenroom/regulations.htm



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com