17 / 28 page ![]() LTC6995-1/LTC6995-2 Rev. B For more information www.analog.com 17 APPLICATIONS INFORMATION Figure 14. Extended POR. Timer Reset During Initial POR Interval. Full POR Interval Provided Once System Signals the OK Figure 15. Long Time Delayed Rising Edge. Delay Time Can Range from 500µs to 4.8 Hours LTC6995-1 SYSTEM RST GND SET OUT V+ DIV RSET R2 R1 0.1µF V+ POR 699512 F14 OUT POL = 0 RST tSTART + 1/2 tOUT 1/2 tOUT TIMER STOPPED SYSTEM OK SYSTEM OK POR POR EXTENDED POR V+ LTC6995-2 OUTPUT RISING EDGE TRIGGERED POL = 0 TRIGGER RST GND SET OUT V+ DIV RSET R2 R1 0.1µF V+ 699512 F15 OUTPUT TRIGGER 1/2 tOUT 1/2 tOUT V+ 1/2 tOUT 1/2 tOUT LTC6995-1 OUTPUT FALLING EDGE TRIGGERED POL = 0 TRIGGER RST GND SET OUT V+ DIV RSET R2 R1 0.1µF V+ OUTPUT TRIGGER V+ |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|