35 / 51 page ![]() 35 of 51 ELM327DSC Elm Electronics – Circuits for the Hobbyist www.elmelectronics.com Altering Flow Control Messages ELM327 ISO 15765-4 (CAN) provides for only eight data bytes per frame of data. Of course, there are many cases where the data which needs to be sent is longer that 8 bytes and CAN has made provision for this, allowing data to be separated into segments, then recombined at the receiver. To send one of these multi-line messages, the transmitter in a CAN system will send a ‘First Frame’ message, and then wait for a reply from the receiver. This reply, called a ‘Flow Control’ message contains information concerning acceptable message timing, etc., and is required to be sent before the transmitter will send any more data. For ISO 15765-4, the type of response is well defined, and never changes. The ELM327 will automatically send this ISO 15765-4 Flow Control response for you as long as the CAN Flow Control option is enabled (CFC1), which it is by default. Several users have requested that we provide more flexibility over the data sent in the Flow Control message, and as of v1.1, we have provided a means to do this. In order to change how the ELM327 responds when it needs to send a Flow Control message, you need to change Flow Control ‘modes’. The default Flow Control mode is number ‘0’. At any time while you are experimenting, if you should wish to restore the automatic Flow Control responses (for ISO 15765-4), simply set the mode to 0: >AT FC SM 0 OK This will immediately restore the responses to their default settings. Mode 1 has been provided for those that need complete control over their Flow Control messages. To use it, simply define the CAN ID (header) and data bytes that you require be sent in response to a First Frame message. If you try to set the mode before defining these values, you will get an error: >AT FC SM 1 ? You must set the headers and data first: >AT FC SH 7E8 OK >AT FC SD 00 11 22 OK then you can set the mode: >AT FC SM 1 OK From this point on, every First Frame message received will be responded to with your custom message. The final mode currently supported allows the user to set the data bytes which are to be sent, but not the ID bits. The ID bits (header bytes) in mode 2 are set to those which were received in the First Frame message, without change. To use this mode, first define your data bytes, then activate the mode: >AT FC SD 00 11 22 OK >AT FC SM 2 OK For most people, there will be little need to manipulate these ‘Flow Control’ messages, as the defaults are designed to work with the CAN OBD standards. If you wish to experiment, these special AT commands offer that control for you. Figure 7 summarizes the currently supported modes: Figure 7. Flow Control Mode Numbers ELM327 Provides FC Mode 0 1 2 ID Bits Data Bytes User Provides ID Bits Data Bytes no values no values ID Bits Data Bytes |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |