58 / 91 page ![]() PCA9665_2 © NXP B.V. 2006. All rights reserved. Product data sheet Rev. 02 — 7 December 2006 58 of 91 NXP Semiconductors PCA9665 Fm+ parallel bus to I2C-bus controller 8.8.4 I2CSTA = 78h This status code indicates that the SCL line is stuck LOW. 8.9 Some special cases The PCA9665 has facilities to handle the following special cases that may occur during a serial transfer. 8.9.1 Simultaneous repeated START conditions from two masters A repeated START condition may be generated in the Master Transmitter or Master Receiver modes. A special case occurs if another master simultaneously generates a repeated START condition (see Figure 15). Until this occurs, arbitration is not lost by either master since they were both transmitting the same data. If the PCA9665 detects a repeated START condition on the I2C-bus before generating a repeated START condition itself, it will use the repeated START as its own and continue with the sending of the slave address. 8.9.2 Data transfer after loss of arbitration Arbitration may be lost in the Master Transmitter and Master Receiver modes. Loss of arbitration is indicated by the following states in I2CSTA; 38h, 68h, and B0h (see Figure 7, Figure 11, Figure 8, and Figure 12). Remark: In order to exit state 38h, a Time-out, Reset, or external STOP are required. If the STA flag in I2CCON is set by the routines which service these states, then, if the bus is free again, a START condition (state 08h) is transmitted without intervention by the CPU, and a retry of the total serial transfer can commence. 8.9.3 Forced access to the I2C-bus In some applications, it may be possible for an uncontrolled source to cause a bus hang-up. In such situations, the problem may be caused by interference, temporary interruption of the bus or a temporary short-circuit between SDA and SCL. If an uncontrolled source generates a superfluous START or masks a STOP condition, then the I2C-bus stays busy indefinitely. If the STA flag is set and bus access is not obtained within a reasonable amount of time, then a forced access to the I2C-bus is possible. If the I2C-bus stays idle for a time period equal to the time-out period, then the PCA9665 concludes that no other master is using the bus and sends a START condition. Fig 15. Simultaneous repeated START conditions from 2 masters S SLA W A DATA A 18h 28h 002aab028 other master sends repeated START condition earlier 08h S both masters continue with SLA transmission |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |