Back Button LTC7890 Datasheet HTML 5Page - Analog Devices LTC7890 Datasheet HTML 6Page - Analog Devices LTC7890 Datasheet HTML 7Page - Analog Devices LTC7890 Datasheet HTML 8Page - Analog Devices LTC7890 Datasheet HTML 9Page - Analog Devices LTC7890 Datasheet HTML 10Page - Analog Devices LTC7890 Datasheet HTML 11Page - Analog Devices LTC7890 Datasheet HTML 12Page - Analog Devices LTC7890 Datasheet HTML 13Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 50 page
background image
Data Sheet
LTC7892
analog.com
Rev. 0
9 of 50
ABSOLUTE MAXIMUM RATINGS
TA = 25°C unless otherwise specified.
Table 2. Absolute Maximum Ratings
PARAMETER
RATING
Bias Input Supply (VBIAS)
–0.3V to 100V
RUN1 and RUN2
–0.3V to 100V
BOOST1 and BOOST2
–0.3V to 106V
SW1 and SW2
–5V to 100V
BOOST1 to SW1 and BOOST2 to SW2
–0.3V to 6V
TGUP1, TGUP2, TGDN1, TGDN21
Not applicable
BGUP1, BGUP2, BGDN1, BGDN21
Not applicable
EXTVCC
–0.3V to 30V
DRVCC and INTVCC
–0.3V to 6V
VFB1
–0.3V to 65V
PLLIN/SPREAD FREQ and VFB2
–0.3V to 6V
SS1, SS2, ITH1, and ITH2
–0.3V to 6V
DRVSET and DRVUV
–0.3V to 6V
MODE, ILIM, and VPRG1
–0.3V to 6V
PGOOD1 and PGOOD2
–0.3V to 6V
DTCA and DTCB
-0.3V to 6V
SENSE1+, SENSE2+, SENSE1–, and SENSE2–
–0.3V to 65V
SENSE1+ to SENSE1– and SENSE2+ to SENSE2– Continuous
–0.3V to +0.3V
SENSE1+ to SENSE1– and SENSE2+ to SENSE2– < 1ms
-100mA to +100mA
Operating Junction Temperature Range2
–40°C to 125°C
Storage Temperature Range
–65°C to 150°C
.
1
Do not apply a voltage or current source to these pins. They must be connected to capacitive loads only.
Otherwise, permanent damage can occur.
2
The LTC7892 is specified over the –40°C to 125°C operating junction temperature range. High junction
temperatures degrade operating lifetimes. Note that the maximum ambient temperature consistent with these
specifications is determined by specific operating conditions in conjunction with the board layout, rated
package thermal impedance, and other environmental factors. The junction temperature (TJ, in °C) is calculated
from the ambient temperature (TA, in °C) and power dissipation (PD, in Watts) according to the following
formula: TJ = TA + (PD × θJA), where θJA is the package thermal impedance and equals 33°C/W for the 40-lead (6
mm × 6 mm), side wettable, quad flat no-lead (QFN) package.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com