Back Button AD5778R Datasheet HTML 16Page - Analog Devices AD5778R Datasheet HTML 17Page - Analog Devices AD5778R Datasheet HTML 18Page - Analog Devices AD5778R Datasheet HTML 19Page - Analog Devices AD5778R Datasheet HTML 20Page - Analog Devices AD5778R Datasheet HTML 21Page - Analog Devices AD5778R Datasheet HTML 22Page - Analog Devices AD5778R Datasheet HTML 23Page - Analog Devices AD5778R Datasheet HTML 24Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 26 page
background image
Data Sheet
AD5778R
THEORY OF OPERATION
analog.com
Rev. 0 | 20 of 26
instructed to update from either Input Register A or Input Register
B.
The internal toggle update circuit is edge triggered, so only transi-
tions (of TGB or TGP) trigger an update from the respective input
register.
To toggle all selected channels together using the SPI port, ensure
the TGP pin and the bits in the toggle select register corresponding
to the desired channels are high. Use the global toggle command
(1101b) to alternate codes, sequentially changing the Global Toggle
Bit TGB (see Figure 28). Changing TGB from 1 to 0 updates the
DAC registers from their respective Input Registers A. Changing
TGB from 0 to 1 updates the DAC registers from their respective
Input Registers B. Note that in this way, one or both channels may
be toggled with just one serial command.
To toggle all selected channels using an external logic signal,
ensure that both the TGB bit in the global toggle register and the
bits corresponding to the desired channels in the toggle select
register are high. Apply a clock or logic signal to the TGP pin to
alternate codes. The TGP falling edges update the DAC registers
from their associated Input Registers A. The TGP rising edges
update the DAC registers from their associated Input Registers B.
Note that once the input registers are set up, all toggling is triggered
by the signal applied to the TGP pin, with no further SPI instructions
needed.
To cause any combination of channels to update from either Input
Register A or Input Register B, ensure the TGP pin and the TGB
bit in the global toggle register are high. Using the toggle select
command, set the toggle select bits as needed to select the input
register (A or B) with which each channel is to be updated. Then
update all channels, either by using the serial command (update all
(power up), 1001b) or by applying a negative pulse to the LDAC
pin. Any channels where the toggle select bits are zero update
from Input Register A. Channels where the toggle select bits are
one update from Input Register B (see Figure 29). By alternating
toggle select and update operations, more than one channel can be
simultaneously switched to A or B as needed.
DAISY-CHAIN OPERATION
The serial output of the shift register appears at the SDO pin. Data
transferred to the device from the SDI input is delayed 32 SCK
rising edges before being output at the next SCK falling edge,
suitable for clocking into the microprocessor on the next 32 SCK
rising edges.
The SDO output can be used to facilitate control of multiple serial
devices from a single 3-wire serial port (SCK, SDI, and CS/LD).
Such a daisy-chain series is configured by connecting the SDO of
each upstream device to the SDI of the next device in the chain.
The shift registers of the devices are thus connected in series,
effectively forming a single input shift register that extends through
the entire chain. Because of this, the devices can be addressed and
controlled individually by simply concatenating their input words.
The first instruction addresses the last device in the chain and so
forth. The SCK and CS/LD signals are common to all devices in the
series.
In use, CS/LD is first taken low. Then, the concatenated input
data is transferred to the chain using the SDI of the first device
as the data input. When the data transfer is complete, CS/LD
is taken high, completing the instruction sequence for all devices
simultaneously. A single device can be controlled by using the
no operation command (1111b) for all other devices in the chain.
When CS/LD is taken high, the SDO pin presents a high impedance
output, so a pull-up resistor is required at the SDO of each device
(except the last) for daisy-chain operation.
ECHO READBACK
The SDO pin can be used to verify data transfer to the device. Dur-
ing each 32-bit instruction cycle, SDO outputs the previous 32-bit
instruction for verification. The 8-bit don’t care prefix is replaced by
four fault register status bits, followed by the 4-bit command and
address words and the full 16-bit data-word (see Figure 3). The
SDO sequence for a 24-bit instruction cycle is the same, except
that the data-word is truncated to 8 bits (see Figure 4). When
CS/LD is high, SDO presents a high-impedance output, releasing
the bus for use by other SPI devices.
FAULT REGISTER (FR)
The AD5778R provides notifications of operational fault conditions.
The fault register (FR) status bits comprise the first data byte
(8 bits) of each 24- or 32-bit SDO word, outputted to the SDO
pin during every SPI transaction. See Figure 3 and Figure 4 for
sequences.
A fault register bit is set when its trigger condition is detected, and
the bit is clocked to SDO during the next SPI transaction. The fault
register information is updated with each SPI transaction. Note that
if a fault condition is corrected by the action of an SPI instruction,
the cleared fault register flag for that condition is observable at SDO
on the next SPI transaction.
Table 11 lists the fault register bits and their associated trigger
conditions.
Table 11. Fault Register
FR
Bit
Fault Condition
FR0 Open-circuit condition detected on OUT0.
FR1 Open-circuit condition detected on OUT1.
FR2
Overtemperature. If the die temperature TJ > 175°C, FR2 is set, and the
thermal protection is activated. The FR2 bit can be disabled using the
CONFIG command (0111b).
FR3
Power Limit. If VDDx − VOUTx > 10 V and the current range is ≥ 200mA, FR3
is set, and the range for that channel is reduced to 100 mA. The FR3 bit
can be disabled using the CONFIG command (0111b).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com