| Electronic Components Datasheet Search |
|
BMM350 Datasheet(PDF) 19 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMM350 Datasheet(HTML) 19 Page - Bosch Sensortec GmbH |
|
19 / 63 page ![]() Bosch Sensortec | BST-BMM350-DS001-27 19 | 63 © Bosch Sensortec GmbH 2023 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, Document number: BST-BMM350-DS001-27 as well as in the event of applications for industrial property rights 5.3 Excessive field strengths handling The BMM350 can handle magnetic field strengths up to +/-2000µT in every X/Y/Z direction. BMM350 has the limitation for measurement range that the sum of absolute values of each axis should be smaller. SQRT(Hx^2 + Hy^2 + Hz^2) = 2000µT An API function “BMM350_check_for_highfield_and_reset” is provided which checks whether the field range has been exceeded, and then automatically magnetically resets the sensor. See chapter 4.1.5 for details. This API function must be called explicitly, it is not called automatically. It should be called directly after “BMM350_read_mag_data_and_compensate”. A programming example is provided with the API. 5.4 Data rate and noise performance setting Output data rate (ODR) is set using register PMU_CMD_AGGR_SET.odr. Noise performance is set in register PMU_CMD_AGGR_SET.avg. In the following text this parameter is also called “averaging” (avg = 0/1/2/3 averaging = 1/2/4/8). An API function “BMM350_set_odr_performance” is provided which both handles data rate and noise performance setting. A higher noise performance trades linearly against power consumption: to achieve a better noise performance several data samples are calculated internally and averaged. This is why current consumption is proportional to the averaging setting/noise performance setting, at least at higher ODR rates. Table 7: Power consumption versus data rate ODR and noise performance setting, allowed combinations of settings. n/a: not allowed. Averaging value/ noise performance setting PMU_CMD_AGGR_SET.avg Noise Mode 8/3 Ultra Low Noise 4/2 Low Noise 2/1 Regular Power 1/0 Low Power Power mode after boot is “suspend mode” when using API function BMM350_init. When changing PMU_CMD_AGGR_SET.odr or PMU_CMD_AGGR_SET.avg it is necessary to send an “update” command via PMU_CMD.pmu_cmd The API function “BMM350_set_odr_performance” does that automatically. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |