| Electronic Components Datasheet Search |
|
BMM350 Datasheet(PDF) 22 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMM350 Datasheet(HTML) 22 Page - Bosch Sensortec GmbH |
|
22 / 63 page ![]() Bosch Sensortec | BST-BMM350-DS001-27 22 | 63 © Bosch Sensortec GmbH 2023 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, Document number: BST-BMM350-DS001-27 as well as in the event of applications for industrial property rights 5.10.2 ERR_REG: PMU and boot error Register ERR_REG indicates PMU- and boot-errors. ERR_REG.pmu_err tells if PMU commands have been issued out-of-time (too early) or in the wrong context. Error conditions are: Forced mode is requested in normal mode (sensor must be in suspend mode if doing that) To prevent the occurrence of such errors it is recommended to use the API function BMM350_set_powermode. 5.10.3 PMU_CMD_STATUS: PMU (command) status PMU_CMD_STATUS_0.pmu_cmd_busy signals that the PMU is not ready to take new commands. Such a busy condition can be encountered after triggering a magnetic reset, which can take up to 8ms. Another busy condition can be met after issuing a second forced mode request immediately after issuing a first forced mode request. The first forced mode request can take longer as expected, depending on the charging condition of the external 2.2uF capacitor. PMU_CMD_STATUS_0.cmd_is_illegal indicates illegal commands. Illegal commands are commands which do not appear in the register description of register PMU_CMD. PMU_CMD_STATUS_0.pwr_mode_is_normal indicates whether the sensor is in normal (power) mode. PMU_CMD_STATUS_1.pmu_odr_s and PMU_CMD_STATUS_1.pmu_odr_s indicate the actual noise/performance setting and data rate setting. To prevent the occurrence of errors it is recommended to use the API function BMM350_set_powermode and BMM350_set_odr_perfromance. 5.10.4 I3C_ERR: I3C status/error reporting I3C is a complex protocol. When bringing up a new system status information may be helpful. I3C_ERR.i3c_err_0 indicates an SDR parity error. See MIPI spec 5.1.2.3.2 Ninth Bit of SDR Master Written Data as Parity. I3C_ERR.i3c_err_1 indicates an S0/S1 error, see MIPI spec 5.1.10.1.2 Error Type S0, 5.1.10.1.3 Error Type S1. 5.10.5 Soft reset, reset detection. A “soft reset” can be used to reset all sensor settings issued so far. The soft reset is triggred by sending CMD.cmd = 0xB6 followed by CMD.cmd = 0x0 An API function BMM350_soft_reset_and_wait()is provided. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |