CW025 Datasheet(PDF) 2 Page - Lineage Power Corporation |
|
|
|||||||||||||||||||||||||||||
CW025 Datasheet(HTML) 2 Page - Lineage Power Corporation |
|
2 / 20 page ![]() 22 Lineage Power Data Sheet April 2008 36 Vdc to 75 Vdc Input; 25 W CW025 Triple-Output-Series Power Modules: Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso- lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Symbol Min Max Unit Input Voltage Continuous VI — 80 Vdc I/O Isolation Voltage: dc Transient (1 minute) — — — — 500 850 V V Operating Case Temperature TC –40 100 °C Storage Temperature Tstg –55 125 °C Electrical Specifications Unless otherwise indicated, specifications apply to all modules over all operating input voltage, resistive load, and temperature conditions. Table 1. Input Specifications Parameter Symbol Min Typ Max Unit Operating Input Voltage VI 36 48 72* Vdc Maximum Input Current (VI = 0 V to 75 V; IO = IO, max) II, max — — 2.0 A Inrush Transient i2t — — 0.2 A2s Input Reflected-ripple Current, Peak-to-peak (5 Hz to 20 MHz, 12 µH source impedance; TC = 25 °C; see Figure 18 and Design Considerations section.) — — 25 — mAp-p Input Ripple Rejection (120 Hz) — — 60 — dB * Operation is specified to 75 V, provided the minimum load on Output 1 is at least 0.75 A. Safety agency reports specify 75 V maximum input. Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus- ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A in series with the ungrounded input lead. Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |