Back Button ADS1259IPWR Datasheet HTML 23Page - Texas Instruments ADS1259IPWR Datasheet HTML 24Page - Texas Instruments ADS1259IPWR Datasheet HTML 25Page - Texas Instruments ADS1259IPWR Datasheet HTML 26Page - Texas Instruments ADS1259IPWR Datasheet HTML 27Page - Texas Instruments ADS1259IPWR Datasheet HTML 28Page - Texas Instruments ADS1259IPWR Datasheet HTML 29Page - Texas Instruments ADS1259IPWR Datasheet HTML 30Page - Texas Instruments ADS1259IPWR Datasheet HTML 31Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 27 / 51 page
background image
DRDY
CS
(DOUTwith
=0)
DIN
t
CAL
CALCommand
Calibrationcomplete
andfirstdataready.
ADS1259
www.ti.com
SBAS424D
– JUNE 2009 – REVISED AUGUST 2011
CALIBRATION
The internal full-scale calibration word is bypassed
during offset calibration. Do not exceed +105% of
The ADS1259 has commands to correct for system
full-scale range for gain calibration. Note that the
offset and gain errors. Calibration can be performed
out-of-range
threshold
is
unaffected
by
gain
at any time the ADS1259 and associated circuitry
calibration.
(such as the input amplifier, external reference, power
supplies,
etc)
have
stabilized.
Options
include
Table 15. Calibration Timing
calibrating after power-up, after temperature changes,
tCAL CALIBRATION TIME (ms)
or calibration at regular intervals. To calibrate:
DATA RATE
(SPS)
sinc1
sinc2
•
Set the gate control mode (PULSE bit = 0)
14400
1.89
2.19
•
Start the ADS1259 conversions
3600
5.43
6.15
•
Apply the appropriate input to the ADS1259 (zero
or full-scale)
1200
14.9
16.7
•
Allow time for the input to completely settle
400
43.2
48.4
60
284
318
•
Send the OFSCAL (offset calibration) or GANCAL
(full-scale calibration) command, as appropriate
50
341
380
•
Wait for calibration to complete as given by the
16.6
1020
1140
time listed in Table 15. DRDY goes low when
10
1700
1900
calibration is complete. The conversion result at
1. fCLK = 7.3728MHz.
this time uses the new offset or full-scale
calibration words.
Figure
56
shows
the
calibration
timing.
During
calibration, do not send commands.
Perform offset calibration prior to the gain calibration.
Figure 56. Calibration Timing
Copyright
© 2009–2011, Texas Instruments Incorporated
27



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com