| Electronic Components Datasheet Search |
|
ADS1259IPWR Datasheet(PDF) 30 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ADS1259IPWR Datasheet(HTML) 30 Page - Texas Instruments |
|
30 / 51 page ![]() SCLK DRDY t DRSC t SCDR 1 9 17 25 33 DRDY (1) CS (2) SCLK (3) DOUT DATAMSB DATAMID DATALSB CHECKSUM (6) DATAMSB (7) DIN (8) DataReady NextDataReady t UPDATE (4) Hi-Z (5) ADS1259 SBAS424D – JUNE 2009 – REVISED AUGUST 2011 www.ti.com DATA RETRIEVAL The Read Data Continuous mode is cancelled by sending the Stop Read Data Continuous command New conversion data are available when DRDY goes (SDATAC). This operation occurs simultaneously with low. Read the data within 20 fCLK cycles of the next ADC conversion data on DOUT which can be DRDY falling edge or the data are incorrect. Do not ignored. Once the SDATAC command is sent, other read data during this interval. The conversion data commands may be sent to the ADS1259. Observe may be read in two ways: Data Read in Continuous the SCLK and DRDY timing requirements, when mode and Data Read in Stop Continuous mode. reading data in this mode, as shown in Figure 59 and Table 18. Data Read Operation in Continuous Mode In Read Data Continuous mode the conversion data may be shifted out directly without the need of the data read command. When DRDY (and DOUT, if CS is low) assert low, the conversion data are ready. The data are shifted out on DOUT on the rising edges of SCLK, with the most significant bit (MSB) clocked out first. In Gate Convert Mode, DRDY returns to high on Figure 59. SCLK to DRDY Timing the first falling edge of SCLK. In Pulse Convert mode, DRDY remains low until a new conversion starts. As shown in Figure 60, the conversion data consist of Table 18. SCLK and DRDY Timing Characteristics three or four bytes (data MSB first), depending on for Figure 57 whether the checksum byte is included. The data SYMBOL DESCRIPTION MIN UNIT may be read multiple times by continuing to shift the tSCDR (1) SCLK low before DRDY data. The data read operation must be completed 20 tCLK low(1) with 20 fCLK cycles of next DRDY falling edge. tDRSC (1) DRDY falling edge to SCLK 40 ns rising edge(1) (1) These requirements apply only to reading conversion data in RDATAC mode. (1) In Gate Convert Conversion mode, DRDY returns to high on the first falling edge of SCLK. In Pulse Convert mode, DRDY remains low until the next conversion is started. (2) CS may be held low. If CS is low, DOUT asserts low with DRDY. (3) Data are updated on the rising edge of SCLK. DOUT is low until the first rising edge of SCLK. (4) tUPDATE = 20/fCLK. Do not read data during this time. (5) During this interval, DOUT follows DRDY. (6) Optional data checksum byte. (7) Optional repeat of previous conversion data. (8) Hold DIN low, except for transmission of the SDATAC (STOP Read Data Continuous command). Figure 60. Data Read Operation in Continuous Mode 30 Copyright © 2009–2011, Texas Instruments Incorporated |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |