  ADS1259IPWR Datasheet HTML 1Page - Texas Instruments ADS1259IPWR Datasheet HTML 2Page - Texas Instruments ADS1259IPWR Datasheet HTML 3Page - Texas Instruments ADS1259IPWR Datasheet HTML 4Page - Texas Instruments ADS1259IPWR Datasheet HTML 5Page - Texas Instruments ADS1259IPWR Datasheet HTML 6Page - Texas Instruments ADS1259IPWR Datasheet HTML 7Page - Texas Instruments ADS1259IPWR Datasheet HTML 8Page - Texas Instruments ADS1259IPWR Datasheet HTML 9Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 51 page
background image
ADS1259
www.ti.com
SBAS424D
– JUNE 2009 – REVISED AUGUST 2011
ELECTRICAL CHARACTERISTICS
Minimum/maximum specifications are at TA = –40°C to +105°C. Typical specifications are at TA = +25°C, AVDD = +2.5V, AVSS = –2.5V,
DVDD = +3.3V, fCLK = 7.3728MHz, VREF = 2.5V, and fDATA = 60SPS, unless otherwise noted.
ADS1259
ADS1259B
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
UNIT
ANALOG INPUTS
Full-scale input voltage range (FSR)
VIN = (AINP – AINN)
±VREF
±VREF
V
Absolute input voltage
AVSS
– 0.1
AVDD + 0.1
AVSS
– 0.1
AVDD + 0.1
V
(AINP, AINN to DGND)
Differential input impedance
120
120
k
Ω
Common-mode input impedance
500
500
k
Ω
SYSTEM PERFORMANCE
Resolution
No missing codes
24
24
Bits
Data rate (fDATA)
10
14400
10
14400
SPS
(1)
Integral nonlinearity
Best fit method
±0.0003
±0.001
±0.00004
(2)
±0.0003
%FSR
Offset error
±40
±250
±40
±250
μV
Offset error after calibration
(3)
±1
±1
μV
Offset drift
(4)
TA = –40°C to +105°C
0.05
0.25
0.05
0.25
μV/°C
Gain error
(5)
±0.05
±0.5
±0.05
±0.5
%
Gain error after calibration
(3)
±0.0002
±0.0002
%
Gain drift
(4)
TA = –40°C to +105°C
0.5
2.5
0.5
2.5
ppm/
°C
Normal mode rejection
See Figure 42
Common-mode rejection
60Hz, ac
(6)
100
120
100
120
dB
Noise
See Table 1
0.7
0.7
μV
AVDD, AVSS power-supply
60Hz, ac
(6)
85
95
85
95
dB
rejection
DVDD power-supply rejection
60Hz, ac
(6)
85
110
85
110
dB
OUT-OF-RANGE DETECTION
Level
±105
±105
%FSR
Threshold
(7)
Accuracy
±0.5
±0.5
%FSR
VOLTAGE REFERENCE INPUTS
VREF = (VREFP –
AVDD
– AVSS +
AVDD
– AVSS +
Reference input range (VREF)
0.5
2.5
0.5
2.5
V
VREFN)
200mV
200mV
Negative reference absolute input
AVSS
–
AVSS
–
VREFP
– 0.5
VREFP
– 0.5
V
(VREFN to DGND)
100mV
100mV
Positive reference absolute input
VREFN + 0.5
AVDD + 100mV
VREFN + 0.5
AVDD + 100mV
V
(VREFP to DGND)
200nA +
200nA +
Average reference input current
(8)
60nA/V
60nA/V
Average reference input current drift
Internal or external clock
0.2
0.2
nA/
°C
INTERNAL VOLTAGE REFERENCE
VREFOUT = (REFOUT –
Reference output voltage
2.5
2.5
V
AVSS)
Accuracy
TA = +25°C
±0.4
±0.2
%
TA = –40°C to +105°C
10
40
4
12
ppm/
°C
Temperature drift
(4)
TA = 0°C to +85°C
2
5
ppm/
°C
Drive current sink and source
–10
10
–10
10
mA
(9)
Load regulation
10
10
μV/mA
Turn-on settling time
(10)
±0.001% settling
1
1
s
Long-term stability
0 to 1000 hours
70
70
ppm/1000hr
Thermal hysteresis
(11)
30
30
ppm
(1)
SPS = samples per second.
(2)
Shaded cells indicate improved specifications of the ADS1259B.
(3)
Calibration accuracy is on the level of noise (signal and ADC), reduced by the effect of 16 reading averaging.
(4)
Reference drift specified by design and final production test. Drift calculated over the specified temperature range using box method.
(5)
Excludes internal reference error.
(6)
fDATA = 14.4kSPS. Placing a notch of the digital filter at 60Hz (setting fDATA = 10SPS or 60SPS) further improves the common-mode
rejection and power-supply rejection of this input frequency.
(7)
Absolute input voltage range for out-of-range specification: AVSS + 150mV
≤ AINP or AINN ≤ AVDD – 150mV.
(8)
Over the range: AVSS
≤ VREFP or VREFN ≤ AVDD. For reference voltage exceeding AVDD or AVSS, input current = 150nA/10mV.
(9)
Limit the reference output current to
±10mA.
(10) CREFOUT = 1μF, CREFIN = 1μF.
(11) See the Thermal Hysteresis section.
Copyright
© 2009–2011, Texas Instruments Incorporated
3



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com