| Electronic Components Datasheet Search |
|
ADS1283IRHFR.B Datasheet(PDF) 39 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ADS1283IRHFR.B Datasheet(HTML) 39 Page - Texas Instruments |
|
39 / 67 page ![]() SCLK DOUT (2) Don't Care Data Byte 1 (MSB) Date Byte 4 (LSB) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 33 34 35 36 37 38 39 40 DIN Command Byte (0001 0010) t DR t DDPD DRDY CS (1) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 25 26 27 28 29 30 31 32 SCLK DOUT (2) Data Byte 1 (MSB) Data Byte 2 (MSB - 1) Data Byte 4 (LSB) DIN t DDPD CS (1) DRDY 39 ADS1283 www.ti.com SBAS565C – JANUARY 2014 – REVISED AUGUST 2019 Product Folder Links: ADS1283 Submit Documentation Feedback Copyright © 2014–2019, Texas Instruments Incorporated (1) DOUT is in tristate when CS is high. Load on DOUT = 20 pF || 100 k Ω. 8.4.8 Reading Data The ADS1283 provides two modes to read conversion data: read-data-continuous and read-data-by-command. 8.4.8.1 Read-Data-Continuous Mode In the read-data-continuous mode, the conversion data are shifted out directly from the device without the need for sending a read command. This mode is the default mode at power-on. This mode is also enabled by the RDATAC command. When DRDY goes low, indicating that new data are available, the MSB of data appears on DOUT, as shown in Figure 53. The data are normally read on the rising edge of SCLK, at the occurrence of the first falling edge of SCLK, DRDY returns high. After 32 bits of data have been shifted out, further SCLK transitions cause DOUT to go low. If desired, the read operation may be stopped at 24 bits. The data shift operation must be completed within four CLK periods before DRDY falls again or the data may be corrupted. When a SDATAC command is issued, the DRDY output is blocked but the ADS1283 continues conversions. In stop continuous mode, the data can only be read by command. (1) DOUT is in tristate when CS is high. CS can be tied low. See Figure 1 for CS low to valid DOUT propagation time. Figure 53. Read Data Continuous Table 17. Timing Data for Figure 53 PARAMETER MIN TYP MAX UNIT tDDPD DRDY to valid MSB on DOUT propagation delay(1) 100 ns 8.4.8.2 Read-Data-By-Command Mode Read-data-continuous mode is stopped by the SDATAC command and put into read-data-by-command mode. In read-data-by-command mode, an RDATA command must be sent to the device for each data conversion (as shown in Figure 54). When the read data command is received (on the eighth SCLK rising edge), data are available to read only when DRDY goes low (tDR). When DRDY goes low, conversion data appear on DOUT. The data may be read on the rising edge of SCLK. (1) DOUT is in tristate when CS is high.CS can be tied low. See Figure 1 for CS low to SCLK rising edge time. Figure 54. Read Data By Command, RDATA (tDDPD timing is given in Table 17) Table 18. Read Data Timing for Figure 54 PARAMETER DESCRIPTION MIN TYP MAX UNIT tDR Time for new data after data read command 0 1 fDATA |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |