Back Button CDCLVD1213 Datasheet HTML 6Page - Texas Instruments CDCLVD1213 Datasheet HTML 7Page - Texas Instruments CDCLVD1213 Datasheet HTML 8Page - Texas Instruments CDCLVD1213 Datasheet HTML 9Page - Texas Instruments CDCLVD1213 Datasheet HTML 10Page - Texas Instruments CDCLVD1213 Datasheet HTML 11Page - Texas Instruments CDCLVD1213 Datasheet HTML 12Page - Texas Instruments CDCLVD1213 Datasheet HTML 13Page - Texas Instruments CDCLVD1213 Datasheet HTML 14Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 25 page
background image
V
T
=
1.25V
100 nF
CDCLVD1213
Z = 50 W
LVDS
Z = 50 W
100 nF
350 W
LVDS
Z = 50 W
CDCLVD1213
Z = 50 W
350 W
LVDS
Z = 50 W
CDCLVD1213
100 W
Z = 50 W
100 nF
100 nF
LVDS
Z = 50 W
CDCLVD1213
100 W
Z = 50 W
10
CDCLVD1213
SCAS897A – JULY 2010 – REVISED OCTOBER 2016
www.ti.com
Product Folder Links: CDCLVD1213
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
8.4.1 LVDS Output Termination
Unused outputs can be left open without connecting any traces to the output pins.
The CDCLVD1213 can be connected to LVDS receiver inputs with DC- and AC-coupling as shown in Figure 9
and Figure 10 (respectively).
Figure 9. Output DC Termination
Figure 10. Output AC Termination (With the Receiver Internally Biased)
8.4.2 Input Termination
The CDCLVD1213 input has an internal 140-Ω termination and can be interfaced with LVDS, LVPECL, or CML
drivers. An external 350-Ω resistor (in parallel with the internal 140-Ω termination) is required to interface with a
50-Ω transmission line.
LVDS drivers can be connected to CDCLVD1213 inputs with DC- and AC-coupling as shown in Figure 11 and
Figure 12 (respectively). With AC coupling, an external bias voltage (VCC/2) must be provided to the VT pin.
Figure 11. LVDS Clock Driver Connected to CDCLVD1213 Input (DC-Coupled)
Figure 12. LVDS Clock Driver Connected to CDCLVD1213 Input (AC-Coupled)
Figure 13 illustrates how to connect a CML input to the CDCLVD1213 input buffer. The input does not have
internal biasing, so external biasing (VCC/2 to VT) is required for AC coupling. If the CML output swing is >1.6
VPP, then signal swing must be reduced to meet VIN, DIF, PP ≤ 1.6 VPP.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com